Repairing/hot air soldering station

Advertisement

Checking and cleaning the desoldering gun obstruated
1. Plug in the power plug, switch on the desoldering func-
tion of the station and let the nozzle heat up.
2. Wait until the nozzle has heated up completely before
you start cleaning.
3. Clean the opening of the nozzle with the cleaning needle.
4. If the cleaning needle does not fit through the opening,
use a cleaning drill instead.
Checking the nozzle for signs of wear
1. Check the condition of the coating on the tip of the
nozzle.
2. The inside of the nozzle and the surface are coated with
a special alloy. If this alloy is damaged by high temperat-
ures, the nozzle can no longer heat up properly and
evenly.
Replacing the heating element
1. Loosen the lock and pull off the housing and nozzle.
2. Remove the old heating element and insert a new one.
3. Reinstall the nozzle and slide the housing back into place. Tighten the locking screw again
properly so that no air can escape. If the locking screw is not tightened properly, the desolder -
ing gun can no longer heat up properly.