Diagram 8, Pipe, Group 1 dangerous fluids 3. Regulation Use The model OVZ is an oval gear, positive displacement flowmeter which can be used to measure and monitor the flowrate of viscous liquid (min. 10 mm²/s to max. 800 mm²/s); (max. viscosity 1000 mm²/s upon request). Only measure clean, non-abrasive liquids with adequate lubricating properties, and against which the materials used in the sensor case are chemically resistant.
4. Operating Principle The OVZ oval wheel meter is a positive- displacement flowmeter. The measuring element comprises two toothed precision oval gearwheels, which are driven by the liquid inlet pressure. As the liquid rotates the gears, a fixed quantity of liquid is transported through the chambers for every turn of the oval-wheel pair.
(filtration 30 m Installation: The OVZ may be installed in any position; the liquid may flow in both directions. Inlet and outlet pipes are not required. The connection threads may be sealed with sealing tape etc.
Meters with cable connections: connect the connection cable with the supply cable. Important! If the connections are incorrectly assigned, the sensor may be seriously damaged. DIN-43650 Plug (OVZ-...l401) Al-housing / Pg 9(OVZ-...l302) Al-Housing / Round plug (OVZ-...l303) PNP (OVZ-...l304) NAMUR (OVZ-...l305) page 6 OVZ K03/0416...
The instruments are pre-adjusted. After electrical connection they are ready for operation. For changing of setting refer to operating manual for compact electronic with frequency output 8.4. Pointer display (..Z300, ..Z340) The instruments are pre-adjusted. After electrical connection they are ready for operation. page 8 OVZ K03/0416...
(option: 1000 mm Ambient temperature: -10 °C to +60 °C Medium temperature: -10 °C to +80 °C Max. pressure: OVZ-..1, OVZ-..2: 10 bar OVZ-..3, OVZ-..4: 16 bar OVZ-..5 : 40 bar Accuracy: ± 2.5 % f. s. Filter mesh size: max.
Page 10
Analogue output (...L303; ...L343, ...L443) Power supply: 24 V ± 20 % Output: 4-20 mA, 0-20 mA, 3-wire Max. load: 500 ohm Electr. connection: connector M12x1 or DIN 43650 Option: plug-on display AUF-3000 (with DIN connector only) page 10 OVZ K03/0416...
..Z340= 240°-pointer indication,4-20 mA, connector M12x1 Digital indicators and transducers to this oval wheel flow meter please see end of brochure. Plug-on display for Model OVZ... L4 ... (with 4-20 mA output and DIN-connector) Description Order number 3-digit LED, plug-connection DIN 43 650...
Insert O-ring; replace cover and firmly tighten screws crosswise. 15. Recommended spare parts 1.0 Pair of oval gearwheels 2.0 NBR, FPM, or EPDM O-ring 3.0 POM, PMMA, PSU, or AL cover Always specify the meter model when ordering spare parts. OVZ K03/0416 page 15...
17. Declaration of Conformance We, Kobold Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Oval Gear Wheel Meter Model: OVZ-... to which this declaration relates is in conformity with the standards noted below: EN 61000-6-2:2006 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for...
Need help?
Do you have a question about the OVZ and is the answer not in the manual?
Questions and answers