Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Refrigerant circuit
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well-
ventilated place.
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
14
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
5. Put the air filter back in.
Cleaning and replacing the HEPA filter
Note
Do not operate the device without a HEPA filter
inserted!
Note
The HEPA filter cannot be washed and must be
replaced if necessary.
Note
The lifetime of the HEPA filter depends on the ambient
conditions and the application period of the device.
• The HEPA filter must be cleaned or replaced if it is very
dirty. This is brought to light e.g. by a reduced capacity
(see chapter Errors and faults).
• Make sure that the HEPA filter is installed before switching
the device on.
The operating life is approx. 1 year, depending on the degree of
air pollution.
If required, visually inspect the HEPA filter for dirt.
dehumidifier TTK 99 HEPA