Locking function
The locking function locks using the buttons on the control
panel.
1. Press the Child Lock button (12) for approx. 3 seconds to
activate the locking function.
ð The Child Lock LED (13) is illuminated.
ð Making inputs on the control panel is locked.
2. Press the Child Lock button (12) for approx. 3 seconds if
you want to deactivate the locking function.
ð The Child Lock LED (13) goes out.
ð The buttons on the control panel are unlocked.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
ü The supplied hose (diameter = 10 mm) is ready for use.
ü The device is switched off.
1. Remove the sealing cap.
2. Push one end of the hose onto the connection for the
condensation drain hose (7).
3. Guide the other hose end to a suitable drain (e.g. floor
drain) or to a sufficiently dimensioned collection container.
Please note that the hose must not be kinked.
EN
4. Remove the hose and attach the sealing cap if you want to
collect the condensate again via the condensation tank.
Allow the hose to dry prior to storage.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running. The duration of the defrost
process can vary. Do not switch off the device during automatic
defrost. Do not remove the mains plug from the mains socket.
The (28) indication is illuminated on the segment display
during automatic defrost.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The following humidity values are suitable for drying laundry:
• cupboard dry = 46 % relative humidity
• iron dry = 58 % relative humidity
• slightly dried = 65 % relative humidity
Adjust the settings for the relative humidity level to the device
(e.g. 60 % relative humidity for iron dry laundry). If necessary,
use a measuring device to determine the humidity level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Press the On/off button (22) to switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.
dehumidifier TTK 99 HEPA
11
Need help?
Do you have a question about the TTK 99 HEPA and is the answer not in the manual?