Advertisement

TTK 95 E
EN
OPERATING MANUAL
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TTK 95 E

  • Page 1 TTK 95 E OPERATING MANUAL DEHUMIDIFIER...
  • Page 2: Table Of Contents

    The scope of delivery may vary from product images. This Symbols document was created with all due care. Trotec GmbH & Co. KG Warning of electrical voltage accepts no liability whatsoever for possible mistakes or omissions.
  • Page 3: Safety

    • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! Operating manual – dehumidifier TTK 95 E...
  • Page 4 Hold onto the mains plug air-conditioning or by Trotec. while doing so. 2. Do not reconnect a defective device to the mains. Operating manual – dehumidifier TTK 95 E...
  • Page 5: Information About The Device

    Designation Control panel Condensation tank with filling level indicator Air inlet with air filter Condensation drain hose connection Power cable winder Air filter Wheels Transport handle Air outlet Operating manual – dehumidifier TTK 95 E...
  • Page 6: Transport And Storage

    • in an upright position where it is protected from dust and direct sunlight • with a cover to protect it from invasive dust if necessary • Place no further devices or objects on top of the device to prevent it from being damaged. Operating manual – dehumidifier TTK 95 E...
  • Page 7 Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device. • Make sure that the air filter is installed before switching the device on. Operating manual – dehumidifier TTK 95 E...
  • Page 8: Operation

    Desired room humidity Is displayed while the desired relative room indication humidity is being set Decrease value button Setting the desired relative room humidity Setting the number of hours for the timer function Operating manual – dehumidifier TTK 95 E...
  • Page 9 2. Press the swing function button (10) again to deactivate the adjusted in increments of 1 h. swing function. The ventilation flap opens completely. Note Do not leave the operating device unattended in a freely accessible room with an activated timer. Operating manual – dehumidifier TTK 95 E...
  • Page 10 Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation. 3. Push one end of the hose onto the hose connection. Operating manual – dehumidifier TTK 95 E...
  • Page 11: Errors And Faults

    Maintenance). If the condenser is dirty, have it of the mains socket. cleaned by a specialist company or by Trotec. • If necessary, remove the condensation drain hose and any • The device might carry out an automatic defrost. During residual fluid from it.
  • Page 12 Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair. Operating manual – dehumidifier TTK 95 E...
  • Page 13: Maintenance

    11. Date: ......12. Date: ......Signature: ......Signature: ......Signature: ......Signature: ......13. Date: ......14. Date: ......15. Date: ......16. Date: ......Signature: ......Signature: ......Signature: ......Signature: ......Operating manual – dehumidifier TTK 95 E...
  • Page 14 5. Put the air filter back in. 2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent. Operating manual – dehumidifier TTK 95 E...
  • Page 15 3. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!). 4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. Operating manual – dehumidifier TTK 95 E...
  • Page 16: Technical Annex

    240 x 368 x 560 (mm) Minimum distance to walls and other objects A: top: 20 cm B: rear: 20 cm C: side: 20 cm D: front: 20 cm Weight 16 kg Wiring diagram SCHEMATICWIRINGDIAGRAM Operating manual – dehumidifier TTK 95 E...
  • Page 17 Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. Operating manual – dehumidifier TTK 95 E...
  • Page 18: Disposal

    The device uses an environmentally and ozone-neutral cooling agent (see Technical Data). Dispose of the refrigerant appropriately and according to the national regulations. Operating manual – dehumidifier TTK 95 E...
  • Page 20 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...