Advertisement

TTK 99 HEPA
EN
OPERATING MANUAL
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TTK 99 HEPA

  • Page 1 TTK 99 HEPA OPERATING MANUAL DEHUMIDIFIER...
  • Page 2: Table Of Contents

    • Check accessories and connection parts for possible Follow the manual damage prior to every use of the device. Do not use any Information marked with this symbol indicates that the defective devices or device parts. operating manual must be observed. dehumidifier TTK 99 HEPA...
  • Page 3 • Only install the device in compliance with the national installation regulations. • Observe the national gas regulations. • Only install, operate and store the device TTK 99 HEPA in a room measuring more than 4 m dehumidifier TTK 99 HEPA...
  • Page 4 Safety chapter. corresponding repair manual is available from the Maintenance tasks which require the housing to be opened manufacturer upon request. must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. dehumidifier TTK 99 HEPA...
  • Page 5: Information About The Device

    In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living and working spaces. Because of the heat radiation generated during operation, the room temperature may rise slightly. dehumidifier TTK 99 HEPA...
  • Page 6: Transport And Storage

    • Leave the device to rest for 12 to 24 hours, so the refrigerant can accumulate within the compressor. Wait 12 to 24 hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided. dehumidifier TTK 99 HEPA...
  • Page 7: Assembly And Start-Up

    • Make sure that no curtains or other objects interfere with the air flow. • When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations. dehumidifier TTK 99 HEPA...
  • Page 8: Operation

    • The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the Mode button For setting the operating mode device is switched off. On/Off LED Illuminated when the device is switched on dehumidifier TTK 99 HEPA...
  • Page 9 ð The device starts in the last selected operating mode, and in automatic mode when it is switched on for the first time. ð The On/off LED (21) is illuminated. ð The LED of the current operating mode (16, 17, 19) is illuminated. dehumidifier TTK 99 HEPA...
  • Page 10 The function can be set in addition in all operating modes. The number of hours can be set in hourly increments (1 h to max. 24 h). When the timer function is active, the Timer LED (29) is illuminated. dehumidifier TTK 99 HEPA...
  • Page 11 • Store the device according to the Transport and storage 3. Guide the other hose end to a suitable drain (e.g. floor chapter. drain) or to a sufficiently dimensioned collection container. Please note that the hose must not be kinked. dehumidifier TTK 99 HEPA...
  • Page 12: Available Accessories

    HEPA filter. • From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec. dehumidifier TTK 99 HEPA...
  • Page 13: Maintenance

    10. Date: ........11. Date: ........12. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........13. Date: ........14. Date: ........15. Date: ........16. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........dehumidifier TTK 99 HEPA...
  • Page 14 (see chapter Errors and faults). • Make sure that the HEPA filter is installed before switching the device on. The operating life is approx. 1 year, depending on the degree of air pollution. If required, visually inspect the HEPA filter for dirt. dehumidifier TTK 99 HEPA...
  • Page 15 3. Clean the HEPA filter with a dry, lint-free cloth if it is slightly dirty. If heavily soiled, dispose of the HEPA filter in accordance with the national regulations and remove the new HEPA filter from the plastic cover. dehumidifier TTK 99 HEPA...
  • Page 16 4. Allow the filter to dry completely. Do not insert a wet filter into the device! 5. Reinsert the air filter into the cover. 2. Remove the filter from the cover. 6. Insert the air inlet cover into the device. dehumidifier TTK 99 HEPA...
  • Page 17: Technical Annex

    51 dB (A) Dimensions (length x width x height) 250 x 370 x 585 mm Minimum distance to walls and other objects A: top 50 cm B: rear 50 cm C: side 50 cm D: front 50 cm Weight 18 kg dehumidifier TTK 99 HEPA...
  • Page 18 Circuit diagram dehumidifier TTK 99 HEPA...
  • Page 19 Water Tank Decorative Strip Indicator Lamp Cover 1 Float Filter Frame Panel Tank Cover Inlet Frame Lampshade Handle Clip Light Board Main Body Duct (up) Indicator Lamp Cover 2 Universal Wheel Motor Capacitor Reed Pipe Base dehumidifier TTK 99 HEPA...
  • Page 20: Disposal

    You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 21 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...