    • Check accessories and connection parts for possible Information marked with this symbol indicates that the damage prior to every use of the device. Do not use any operating manual must be observed. defective devices or device parts. dehumidifier TTK 90 E...
  • Page 3 This serves to avoid fire or explosion • maintaining the dryness of: hazards resulting from an ignition of the refrigerant by an – storage spaces, archives, laboratories, garages electric furnace, cooking stove or another ignition source. – changing rooms etc. dehumidifier TTK 90 E...
  • Page 4 The device does not have the appropriate protection class for use in wet rooms. There is a risk of electric shock! Never use the device in wet rooms (e.g. in bathrooms and laundry rooms) and never immerse the device in water! dehumidifier TTK 90 E...
  • Page 5: Information About The Device

    In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces. Because of the heat radiation generated during operation, the room temperature may rise slightly. dehumidifier TTK 90 E...
  • Page 6: Transport And Storage

    • If required, use a cover to protect the device from invasive Air filter dust. Transport handle • Place no further devices or objects on top of the device to Condensation tank prevent it from being damaged. Air inlet with air filter Control panel dehumidifier TTK 90 E...
  • Page 7: Assembly And Start-Up

    • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater). • Only put up the device in an upright, stable position on firm ground. dehumidifier TTK 90 E...
  • Page 8: Operation

    Setting the temperature unit increments of 5 %. (°C or °F) 1. Press the arrow buttons (15, 16) to adjust the relative room humidity. ð The desired relative room humidity will be indicated on the humidity level segment display (18). dehumidifier TTK 90 E...
  • Page 9 ð The set operating time will be indicated for a few seconds on the segment display (19). Afterwards, the current temperature is displayed again. Note regarding automatic switch-off: • Pressing the On / Off button (22) deactivates the automatic switch-off function. dehumidifier TTK 90 E...
  • Page 10 The automatic defrost LED (11) is illuminated throughout the defrost process. The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket. dehumidifier TTK 90 E...
  • Page 11: Errors And Faults

    • From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec. • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
  • Page 12 50 °C. comply with the technical Temperature data. sensor – short circuit Should the alarm persist, please contact the customer service. Chip communication Switch off the device and failure call the customer service. dehumidifier TTK 90 E...
  • Page 13: Maintenance

    10. Date: ........11. Date: ........12. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... 13. Date: ......... 14. Date: ........15. Date: ........16. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... dehumidifier TTK 90 E...
  • Page 14 3. Check the inside of the device for dirt. 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air-conditioning or by Trotec. dehumidifier TTK 90 E...
  • Page 15 2. Empty the condensation tank over a drain or sink. 3. Rinse the condensation tank with clear water. Regularly clean the condensation tank using a mild cleaning agent (no detergent!). 6. Refit the condensation tank into the device. dehumidifier TTK 90 E...
  • Page 16: Technical Annex

    If you do not intend to use the device for a considerable time: other objects • Store the device according to the Transport and storage A: top: 50 cm chapter. B: rear: 50 cm C: side: 50 cm D: front: 50 cm Weight 14 kg dehumidifier TTK 90 E...
  • Page 17 Circuit diagram AC CORD WHITE CAPACITOR BLUE COMPRESSOR YELLOW T1AL 250V CN 7 FUSE F/MOTOR CN 1 CAPACITOR CN 3 CN 4 CN 2 CN 1 REED CONTROL BOARD SWITCH H.sensor T.sensor BLUE dehumidifier TTK 90 E...
  • Page 18 Overview of spare parts Note: The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. dehumidifier TTK 90 E...
  • Page 19: Disposal

    EU countries on the website in an environmentally friendly manner. https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 20 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

Table of Contents