Jacuzzi LLUSION 6636 Installation And Operating Instructions Manual page 18

Combination air bath and whirlpool
Table of Contents

Advertisement

Available languages

Available languages

General Whirlpool Bath Troubleshooting Guide
PROBLEM
Pump/Motor does not start.
Pump/Motor operates but no fully
adjustable jets are functioning.
Pump/Motor operates but air is not
injected into water.
Pump/motor does not shutoff.
Water leakage from pump unions.
Pump/motor shuts off by itself or with
wall timer, before set time elapses.
Chromotherapy lights fail to operate.
Note: If unit is within the warranty period, contact Jacuzzi Whirlpool Bath
number before work is started. The Serial Number is located on the Specification/Serial Number Plate. See page 15.
Jacuzzi Whirlpool Bath
©
BR28000B 4/05
PROBABLE CAUSES
No power to pump/motor.
Pump/motor not plugged in.
Magic Touch switch - air tube not
connected to switch or to air switch
on pump/motor.
Pump/motor faulty.
Jets are closed.
Suction cover may be clogged.
Air valves closed.
Magic Touch switch - air tube not
connected to switch or to air switch
on pump/motor.
If a wall timer is used, the timer is
defective
Overtightened, O-ring may be
pinched or improperly seated, under
tightened.
Motor thermal protection has
deactivated pump/motor due to
overheating. (Supply voltage low.)
GFCI tripped.
Inadequate supply wiring.
Fiber-optic connector has come
loose.
©
14
REMEDY
Reset GFCI.
Insert plug fully into outlet.
Reconnect tube to Magic Touch switch or
to air switch pump/motor.
Replace pump/motor assembly.
Open jets by rotate counterclockwise.
With motor turned OFF, remove safety
cover and remove any debris. Replace
suction cover before operating.
Open air control valves.
Reconnect tube to Magic Touch switch or
to air switch pump/motor.
Replace timer.
Untighten unions check and reseat O-ring.
If O-ring has been pinched out of shape,
replace (refer to number below). When
tightening union nuts, hand tighten only.
Let motor cool; thermal protection will
reset. Check for proper ventilation.
(Check supply voltage.)
Reset GFCI. If it continues to trip do not
use this unit. Disconnect the unit and
have the problem corrected by a licensed
electrician before using.
Consult a licensed electrician to correct
wiring to unit.
Consult the nearest Jacuzzi authorized service
agent.
Service Support at 1 - (800) 288-4002 with bath's serial

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Allusion 7236Allusion 7242

Table of Contents