AREAS OF
APPLICATION
Submersible pumps in the MultiCut
range are suitable for the drainage of
single dwellings.
MultiCut pumps are principally used
for:
- effluent containing fibrous matter
- effluent containing solids (without
stones)
- domestic effluent without faecal
matter
- domestic effluent with faecal mat-
ter
- mechanically cleaned effluent
The submersible pumps MultiCut ...
TAN, EX are supplied with explosion
protection.
When using the pumps, the relevant
national laws, regulations and stipula-
tions must be adhered to, for example:
• Installation of lowvoltage systems
(e.g., VDE 0100 in Germany)
• Safety
and
working
(e.g., BetrSichV and BGR 500 in Ger-
many)
• Safety
in
wastewater
(e.g., GUV-V C5, GUV-R 104, GUV-
R 126 in Germany)
• Electrical systems and operating re-
sources (e.g., GUV-VA3 in Germany)
• Explosion protection
EN 60079-0, EN 60079-1, EN 60079-
14, EN 60079-17 and EN 1127-1.
For non-standard utilisation conditions
in areas subject to explosion hazards,
please ask the local authority respon-
sible.
In Germany, this would be, for example,
the Trade Supervisory Centre (Gewer-
beaufsicht), the Technical Inspection
Agency (TÜV), the building authority
(Bauamt) or professional organisation
(Berufsgenossenschaft).
The installation and operation of this
equipment is regulated by the ordinance
concerning the protection of health and
safety in the provision of work equipment
and its use at work, concerning safety
when operating installations subject to
monitoring, and concerning the organi-
sation of industrial health and safety at
work, (Betriebssicherheitsverordnung),
Article 1.
Modes of operation
with the pumped medium at a temper-
ature of 40°C:
Motor submersed: continuous opera-
tion S1
Motor emerged: short duration opera-
tion S2; see "Technical Data"
Motor emerged: intermittent operation
S3; see "Technical Data"
The submersible pump is frost-resist-
ant down to -20°C when stored in dry
conditions. When installed, however,
it must not be allowed to freeze in the
water.
Transport
The pump must never be lifted
by the power supply cable! The
pump should only be lowered by
using a chain.
ELECTRICAL
CONNECTION
By using our controls, you can be
sure that the requirements of the EU
type-testing certificate are met.
Only qualified electricians may
materials
carry out electrical works to
the pump or the controls.
The standards applicable in each case
systems
(e.g. EN), the country-specific regu-
lations (e.g. VDE in Germany), and the
regulations of the local supply network
operator must be observed.
ATTENTION! Never lay the end of ca-
bles in water! Penetrating water may
cause malfunctions.
Alterations to the circuitry are to be
made using crimp connectors (X) be-
tween the coni plug connection (Y) and
the built-in motor. The new crimp con-
nection must be professionally made.
Only slow-blow fuses or automatic fus-
es with C or D characteristics are to be
used as pre-fuses for the pump. Nec-
essary fuse protection for direct on-line
start: 16 A.
Δ-Circuitry for low voltage
ENGLISH
Y-Circuitry for high voltage
The pump must be protected via an
overload trip. Setting for direct on-line
start = nominal current.
If the protective device has been trig-
gered, the cause of the malfunction
must be eliminated before switching on
again.
Coil thermostats
ATTENTION! In addition to the overload
trip or protective switch of the motor,
the thermostats integrated in the motor
winding must also be connected. The
thermostats are suitable for 250 V / 1.2
A (cos phi = 0.6) and are labelled 30 and
32 for connection purposes.
For this reason, after the protective
device has been triggered, the mains
cable must be unplugged before rem-
edying the cause of the failure, as oth-
erwise the pump will be automatically
switched on again.
Thermostat connection with explo-
sion protection
The thermostats are to be connected in
such a way that the motor is switched
off via the control circuit when the re-
sponse temperature is reached. It must
not be possible for the motor to switch
on again automatically after the winding
has cooled down.
After an automatic cut-out via
the temperature limiters, the
cause of the malfunction must
first be eliminated. Only then may the
motor be switched on again manually.
The restart interlock must be "non-re-
setting on power failure", i.e. the lock
must be in place to prevent restarting
even after a power cut (in Europe: Di-
rective 2014/34/EU, Appendix II 1.5, EN
60079-17 Table1, B10).
Operation with frequency converter
Frequency converters may only be used
for controlling the frequency of special
models of three-phase pumps. Alter-
9