Connecting

6.3 Overview of rack wiring

Mechanical and climatic environmental conditions (Page 59)
6.3
Overview of rack wiring
There are terminals for the supply voltage on the rack.
Supply voltage (Page 43)
Power supply
Note the technical specifications and the information on the supply voltage in the section "Notes
on operation (Page 35)".
Terminals for power supply
Observe the wiring rules for the SIMATIC CN 4100 communication system.
Notes on wiring (Page 36)
Connecting or disconnecting the power supply
Connecting the supply voltage to the rack (Page 44)
Disconnecting the supply voltage from the rack (Page 44)
38
Crimping TWIN end sleeves at the correct angle
Cross-section of the terminal compartment
a: 1.8 mm
b: 2.4 mm
Spring release
CN 4100 Communication System
Equipment Manual, 10/2021, A5E50871363-AA