Title:
How to Confirm Fault Type When
Control Panel in Zone Fault Status
Product:
Alarm Device

Description

When control panel is in disarm status, it shows "Zone Fault" for some zones. In
this case, control panel can not arm system successfully.

Problem Checking Flow

Zone Fault
Detector is in
Remove Detector,
Replaced with an
EOL directly
Connect to zone
terminal
Disappears?
Measure Voltage
between zone' s
terminal Z and G
Voltage in
故障是否消失
Normal Range
Control Panel Fault
Version:
Page:
Yes
alarm
NO
No
Yes
Fault
NO
Yes
NO
v1.0
Date:
1 of 3
Keep Detector in
Yes
Normal Statues,
Fault
Disappears?
NO
Detector Fault or
探测器故障
Wiring Fault
Detector Fault or
总线接线问题
Wiring Fault
7/11/2017
NO Problem in
Detector and
Control Panel

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-19A08-BNG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION DS-19A08-BNG

  • Page 1 Title: How to Confirm Fault Type When Version: v1.0 Date: 7/11/2017 Control Panel in Zone Fault Status Product: Alarm Device Page: 1 of 3 Description When control panel is in disarm status, it shows “Zone Fault” for some zones. In this case, control panel can not arm system successfully.
  • Page 2 Title: How to Confirm Fault Type When Version: v1.0 Date: 7/11/2017 Control Panel in Zone Fault Status Product: Alarm Device Page: 2 of 3 Detail Steps Step 1: Check whether the Detector is in Alarm Status If detector is in alarm status, eliminate all the factors that will cause alarm for detector. If detecor still can not go back to normal status, we can confirm it is detector fault;...
  • Page 3 Title: How to Confirm Fault Type When Version: v1.0 Date: 7/11/2017 Control Panel in Zone Fault Status Product: Alarm Device Page: 3 of 3 First Choice for Security Professionals HIKVISION Technical Support...

Table of Contents