Operation - Samoa 391020.270 Parts And Technical Service Manual

Pump hoist for 185 kg drums
Table of Contents

Advertisement

Available languages

Available languages

OPERATION

To raise the inductor for the first time:
1. Ensure there is nothing above the hoist. In addition, read the
WARNINGS AND PRECAUTIONS on page 2 and 3.
2. Move the control cabinet lever to the "UP" position (2). Do not
touch any part of the unit while it is moving!
To raise the inductor (normal operation):
1. Before raising the inductor, the pump control valve must be in the
"OFF" position (1).
2. Move the control cabinet lever to the "UP" position (2). If the unit
include follower plate open vacuum release valve (3).
3. Lift the pump higher than the top of the drum. Close vacuum
release valve (3).
DRUM INSTALLATION
1. Check that the control cabinet lever is in the "UP" position (2) (fig.
11).
2. Place the 200 kg drum. Always use drums that are compatible with
this unit. Do not use damaged drums.
3. (For follower plate model only). Unscrew the bleed rod from the
inductor plate, keeping it nearby.
4. Move the control cabinet lever to the "DOWN" position (2) (fig. 11).
FLUID SUPPLY
1. Start the pump by placing the "Pump Control" valve in the "ON"
position (1) (fig. 11).
2. The pump/inductor can now supply fluid through the output hose
until the drum is empty, the speed of emptying can be monitored
by opening and closing the end of the output hose.
3. Before raising the inductor to replace the drum, the pump control
valve must be in the "OFF" position.
WARNING: While the equipment is connected to the air line,
!
be aware of the danger of being trapped by the mobile
elements of this equipment.
OVERPRESSURE SECURITY VALVE (ONLY FOR 754205 MODEL)
To be sure that overpressure valve (1) and non-return valve (2) are clean
and safe, without any drum in the equipment select raise position in
control box open the vacuum release valve. Pull the ring on the security
valve (2), this should be soft and the air should get out throw the valve
exhaust.
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
1
2
5. (Only for follower plate model) let the inductor plate descend
through the drum. When the air stops and the fluid starts to flow
through the bleed hole screw the bleed rod.
6. (For model 391020.270 only). Tighten the drum stops. Insert the
rod and tighten it correctly. The unit is now ready to work with. The
pump should already be operative.
4. Move the control cabinet lever to the "UP" position (2) (fig. 11). In
this position the cylinder go up in the unit. Only with follower plate
model, open the vacuum released valve, a current of air enters the
drum to push the inductor plate (3) (fig. 11).
5. Lift the inductor.
6. Only for follower plate model close the vacuum released valve.
(3) (fig. 11).
For your own security and to prolong your pumps lifetime unplug the
air inlet coupler after using this equipment.
EN
3
Fig. 11
2
1
Fig. 12