WAGNER GM 2800EA Operating Manual page 33

Hide thumbs Also See for GM 2800EA:
Table of Contents

Advertisement

EDITION 10/2005
OPERATING MANUAL
Trouble shooting and solutions
Problem
No wraparound
Leaking material the nozzle
Note:
*=Positions are shown in the part list and drawing of paragraph 10.2
PART NO. DOC0388891
Cause
• No high voltage
• Defective sealing (71)*
in gun barrel
• Air-passages damp
• Damaged valve seat in
the collar (18)*
• Damaged needle head
(73)*
• Seal (29)* or seal (71)*
tighten to fast
GM 2800EA
Solution
• Check function of control
unit in accordance with its
manual
• Switch on HV-switch
• Repair by WAGNER Service
• Clean airpassages and
drying
• Check the seal tightness
with air. If not tight, change
the needle head. and
nozzle
• Change needle head
• Adjust sealing screw (28)*
or sealing screw (70)* until
valve stem is closed, or
replace seals.