30/36

Operation

Error
No error
Operating voltage
UB < UBmin
UB too low
Operating voltage
UB > UBmax
UB too high
Cable break,
(Ucomm = 0 V) error
command value
cannot be recognized;
0..±10 V
behavior of the
output stages as with
command value = 0 V
(corresponds to 0 %)
Cable break,
Icomm < 2 mA
command value
+4..20 mA
Overcurrent,
Icomm > ca. 35 mA
command value
-4..20 mA [1]
Cable break,
Error is only
solenoid
recognized when >
3.5 %
Overcurrent
E.g. short-circuited
solenoid/output
solenoid
stages
Serious error
Internal parameter
memory (EEPROM)
defective
Serious error
Main controller does
not work
Bosch Rexroth AG, Valve amplifier VT-MSPA, RE 30232-B/08.2020
9 Operation
Should a fault occur during operation, e.g. a power failure, the VT-MSPA...-2X can
simply be switched on again without further measures and it is then ready for
operation again.
If the VT-MSPA..-2X.. detects an error, a reaction takes place according to the table
below.
LED
Remark
(red/green)
ready
Permanently
on green
Permanently
on red
Flashing
green
Permanently
on green
Permanently
on red
Permanently
on red
Permanently
on red
Permanently
on red
Permanently
on red
Fast blinking
red & green
Table 9: Error evaluation
The "error" voltage at test jack "v" is automatically output as long as the erroneous
state persists (= LED "ready" is permanently on red).
When the above causes of error are eliminated the amplifier module automatically
resumes operation according to its intended use.
[1] For resetting the overload protection circuit the command value has to be briefly
withdrawn from the module.
In the case of serious errors the module must be replaced.
LED
(yellow)
LEDs (yellow)
"digital
"functions"
input"
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Normal
indication
indication
Normal
Permanently
indication
on (all 8)
Fast
Fast blinking
blinking
(all 8)
Solenoid
Output
output
"ready"
stages
Normal
Normal
operation
operation
Switched off Switched off
Normal
Normal
operation
operation
Normal
Normal
operation
operation
Switched off Switched off
Switched off Switched off
Normal
Switched off
operation
Switched off Switched off
Switched off Switched off
Switched off Switched off
Output at
test jack "v"
Normal
operation
7 V
Normal
operation
Normal
operation
4 V
4 V
6 V
(solenoid B)
5 V
(solenoid A)
8 V
9 V
-14 V