Cooling Module - Seagate OneStor SP-3584 Installation & User Manual

Table of Contents

Advertisement

OneStor® SP-3584 Installation & User Guide
Figure 2–8

2.5 Cooling Module

The five cooling modules at the rear of the enclosure maintain all system components below their
maximum temperature, assuming the ambient temperature is below 35°C.
The speed of the fans in the cooling modules is controlled by the SBB I/O modules. Section
2.5.1, "System Airflow", on page 17
Cooling modules can be hot-swapped while the enclosure is still running, assuming that only one
module is removed at a time and the swap takes no longer than two minutes. Ensure you have a
replacement cooling module before you remove the defective cooling module.
16
PSU LEDs
describes the system airflow.