Components (Fully Populated); Thermal; Temperature And Humidity; Cooling Modules - Seagate OneStor SP-3584 Installation & User Manual

Table of Contents

Advertisement

OneStor® SP-3584 Installation & User Guide
A.3 Components (Fully Populated)
Drawers
Disk Drives In Carriers (DDICs) 84
SBB I/O modules
PSUs

Cooling modules

A.4 Thermal
Thermal sensors
Airflow with all fans running
A.5 Temperature and Humidity
Table A–2
Temperature range
Relative humidity
Maximum wet bulb
A.6 Cooling Modules
Cooling fans
58
2
2
2
5
2 per sideplane (2 sideplanes per drawer)
2 per drawer baseplane (front)
1 per drawer baseplane (middle/rear)
2 per power supply
Number in SBB I/O module is dependent on module type
120 litres/second maximum
Temperature and Humidity Limits
Operating
5°C to 35°C
20%rh to 80%rh
non-condensing
28°C
2 stacked fans: 80x80x38mm
Non-operating
-40°C to 70°C
5%rh to 100%rh
non-condensing
29°C

Hide quick links: