4) When the automatic testing is finished, the buzzer will hint by tweet (buzzer), VFD reads
the result of testing. If the testing passed, VFD reads PASS, or reads FAULT. Press▲、▼
also to observe the numerical value and result of every step.
5) Press
to back the automatic testing.
Esc
Select the Resolution between Low Range and High Range
1)
Press
+
Shift
2)
Press
into the submenu, VFD displays>INITIAL CONFIG
Enter
3)
Press▼to make VFD display RANGE SELECT
4)
Press
to confirm, and press▼to choose ON
Enter
5)
Press
to confirm
Enter
6)
Press
to exit menu
Esc
Then you can press
maximum voltage value is 120V and the resoulution is 10mV, it will become 18V when you
press
+▲ , and you will get 3 decimal points (xx.xxx) compared to 2 decimal points
Shift
before. Wheras if the former maximum voltage is 18V, you can press
become 120V, also the resolution will become as 10mV.
On the other hand, you can press
current). If the former maximum current value is 12A and the resolution is 1mA, it will
become 120A when you press
to 3 decimal points before. wheras if the fromer maximum current is 120A, you can press
+▼ to make it become 12A, and the resolution will become as 1mA.
Shift
to enter into menu, VFD displays>CONFIG
Menu
+▲ to change the voltage range (maximum voltage). If the former
Shift
Shift
+▼, and you will get 2 decimal points (xx.xx) compared
Shift
FRONT PANEL OPERATION
+▼ to change the currnet range (maximum
+▼ to make it
Shift
USER'S GUIDE 39