GENERAL INFORMATION
Con stan t Po wer ( CW ) M o d e
In this mode, the electronic loads will consumption power accordance with the programmed value
regardless of the input voltage. The CW mode can be set with front panel keys. The CW mode
parameters are discussed in the following paragraphs.
Con ti n u o u s
Generates a repetitive pulse stream the toggles between two load levels and change the state
between value A and value B.
P u l se
Switch to value B as receiving one trigger signal , taking the pulse time(TWD) of value B ,
Load will return to Value A .
16 USER'S GUIDE
10A
5A
2.0ms
Continuous Transient Operation
10A
5A
TWD
10ms
TRIG
Pulsed Transient Operation
3.0ms
TWD
10ms
TRIG