SPECIFICATIONS
Electrical Requirements
Model 94812 ....................... 12 VDC @ 3.5 amps
Model 94824 ....................... 24 VDC @ 2 amps
Enclosure Rating ................ IP 6K9K - Protected from water
On Time ............................... 2 minutes minimum
Off Time .............................. 1 hour minimum
Pump Output ....................... 0.171 cu. in./min (2.8 cm/min)
Outlet Connection .............. 1/8" NPT (female)
Maximum Recommended
Operating Pressure ........ 3600 psi (248 bar)
Reservoir Capacity ............ 488 cu. in. (8000 cc)
Lubricant ............................. Greases up to NLGI grade 2
Temperature Range ........... - 13°F(-25°C) to
Pressure Relief Valve ........ 4000 psi +/- 250 psi
JULY - 04
SHOP ONLINE at www.airlinehyd.com
CHASSIS LUBE ELECTRIC GREASE PUMP
OWNER/OPERATOR MANUAL
sprayed in all directions.
30 minutes maximum
in 2 minute increments
15 hours maximum
in 1 hour increments
(depending on the operating
temperature and type of
lubricant)
+158°F(+70°C)
(276 bar) +/- (17 bar)
One Lincoln Way
St. Louis, Missouri 63120-1578
(314) 679-4200
Models 94812, 94824
DESCRIPTION
The chassis lube pump is electrically operated and used in a
progressive type centralized lubrication system. The pump
consists of a pump housing, electric gear motor, a timer and
a plastic reservoir with stirring paddle. The high operating
pressure allows the pump to supply lubricant up to NLGI #2
grease.
MOUNTING THE PUMP
Select an easily accessible place of installation which allows
access to the timer and lubricant reservoir filler fitting. The
pump must be mounted vertically on an even surface by
means of three bolts. (See Fig. 1 on page 3.)
TO FILL RESERVOIR
Fill the reservoir through the grease fitting located at the base
of the reservoir, using a hand operated grease pump. Refill
reservoir when grease reaches "MIN" mark located on the
reservoir. Fill the reservoir up to the "MAX" mark located on
the reservoir.
TO PRIME SYSTEM
Pump & Supply Line: After reservoir has been filled with
recommended lubricant, loosen the supply line fitting. Operate
the pump until lubricant flows from outlet, then tighten fitting.
Feed Lines: Pre-fill each feed line with lubricant before
connecting to outlet of divider valve and bearing.
Copyright 2004
Printed in U.S.A.
Series "C"
- Q3
Section
- 8F
Page
FORM 403493
800-999-7378
Need help?
Do you have a question about the C Series and is the answer not in the manual?
Questions and answers