Nominal ratings
01-...
Input
Output
current
current
I
I
1
2
A
A
273A-2
273
273
U
= 440...480 V, P
at U
= 3-phase 460 V, 60 Hz
1
n
n
02A1-4
2.1
2.1
03A0-4
3.0
3.0
03A5-4
3.5
3.5
04A8-4
4.8
4.8
06A0-4
6.0
6.0
07A6-4
7.6
7.6
012A-4
12.0
12.0
014A-4
14.0
14.0
023A-4
23.0
23.0
027A-4
27.0
27.0
034A-4
34.0
34.0
044A-4
44.0
44.0
052A-4
52
52
065A-4
62
62
077A-4
77
77
078A-4
78
78
096A-4
106
106
124A-4
124
124
156A-4
156
156
180A-4
180
180
240A-4
240
240
260A-4
260
260
302A-4
302
302
361A-4
361
361
414A-4
414
414
U
= 500...600 V, P
at U
= 3-phase 575 V, 60 Hz
1
n
n
02A7-6
2.7
2.7
03A9-6
3.9
3.9
06A1-6
6.1
6.1
09A0-6
9.0
9.0
011A-6
11.0
11.0
017A-6
17.0
17.0
022A-6
22
22
027A-6
27
27
032A-6
32
32
041A-6
41
41
052A-6
52
52
062A-6
62
62
077A-6
77
77
099A-6
99
99
125A-6
125
125
144A-6
144
144
192A-6
192
192
242A-6
242
242
271A-6
271
271
1) Typical motor power with no overload capacity (nominal use). The kilowatt ratings apply to most IEC 4-pole motors. The
horsepower ratings apply to most NEMA 4-pole motors.
2) For IEC installations, ABB recommends aR fuses. See hardware manual for guidelines in selecting between aR and gG
fuses, and for additional fuse alternatives.
3)The recommended branch protection fuses must be used to maintain the IEC/EN/UL 61800-5-1 and CSA C22.2 No. 274
certifications. Refer to note 5 for circuit breaker protection.
4) IEC 61439-1: The drive is suitable for use on a circuit capable of delivering not more than 65 kA when protected by the
fuses given in this table.
5) UL 61800-5-1, CSA C22.2 No. 274: The drive is suitable for use on a circuit capable of delivering not more than 100 kA
symmetrical amperes (rms) at 600 V maximum when protected by the ABB recommended fuses.
Alternate Fuses, MMPs and Circuit Breakers for ABB Drives
6) Refer to
and circuit breakers that can be used as branch circuit protection.
7) Class J, CC, and CF fuses are also allowed at the same nominal current and voltage ratings.
8) IEC Installations: The cable sizing is based on max. 9 cables laid on a cable ladder side by side, three ladder type trays one
on top of the other, ambient temperature 30 °C, PVC insulation, surface temperature 70 °C (EN 60204-1 and IEC 60364-5-
Motor
gG fuse
1)
power
(IEC 60269)
P
n
ABB type
kW
hp
75
100
OFAF2H400
0.75
1.0
OFAF000H4
1.1
1.5
OFAF000H6
1.5
2.0
OFAF000H6
2.2
3.0
OFAF000H10
3.0
3.0
OFAF000H10
4.0
5.0
OFAF000H16
5.5
7.5
OFAF000H16
7.5
10.0
OFAF000H25
11.0
15.0
OFAF000H32
15.0
20.0
OFAF000H40
18.5
25.0
OFAF000H50
22.0
30.0
OFAF000H63
30
40
OFAF000H80
37
50
OFAF000H100
-
60
-
45
60
OFAF000H100
55
75
OFAF00H125
75
100
OFAF00H160
90
125
OFAF0H250
110
150
OFAF1H315
132
200
OFAF1H355
160
200
OFAF2H425
-
250
-
200
300
OFAF2H500
250
350
OFAF3H630
1.5
2.0
-
2.2
3.0
-
4.0
5.0
-
5.5
7.5
-
7.5
10.0
-
11.0
15.0
-
15.0
20.0
-
18.5
25.0
-
22.0
30.0
-
30
40
-
37
50
-
45
60
-
55
75
-
75
100
-
90
125
-
110
150
-
150
200
-
180
250
-
180
250
-
3)
Fuses
uR/aR
UL class
2)4)
5)6)7)
fuse
T
(DIN 43620)
Bussmann type
170M6810
JJS-400
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1563
JJS-30
170M1563
JJS-30
170M1565
JJS-40
170M1565
JJS-60
170M1566
JJS-60
170M1567
JJS-80
170M1568
JJS-100
-
JJS-100
170M1569
JJS-110
170M3817
JJS-150
170M3817
JJS-200
170M5809
JJS-225
170M5810
JJS-300
170M5812
JJS-350
170M6812D
JJS-400
-
JJS-500
170M6814D
JJS-500
170M8554D
JJS-600
-
JJS-15
-
JJS-15
-
JJS-15
-
JJS-15
-
JJS-15
-
JJS-30
-
JJS-40
-
JJS-40
-
JJS-40
-
JJS-100
-
JJS-100
-
JJS-100
-
JJS-100
-
JJS-150
-
JJS-200
-
JJS-250
-
JJS-300
-
JJS-400
-
JJS-400
(3AXD50000645015
Typical power cable sizes,
Cu
2 8)
9)
mm
AWG
2×(3×70 + 35)
500 MCM
or 2×2/0
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×2.5 + 2.5
14
3×2.5 + 2.5
14
3×2.5 + 2.5
12
3×6 + 6
10
3×10 + 10
8
3×10 + 10
8
3×10 + 10
6
3×25 + 16
4
3×35 + 16
4
-
3
3×50 + 25
3
3×70 + 35
1/0
3×95 + 50
2/0
3×120 + 70
3/0
3×150 + 70
4/0
2×(3×70+35)
2×1/0 or
350 MCM
2×(3×95+50)
2×2/0
-
2×3/0
2×(3×120+70)
2×4/0
2×(3×150+70)
2×300
MCM
-
14
-
14
-
14
-
14
-
14
-
10
-
10
-
8
-
8
-
6
-
4
-
2
-
2
-
1/0
-
3/0
-
4/0
-
300 MCM
-
500 MCM
-
2x250
MCM
[English]) for additional UL fuses
13
Frame
size
R8
R1
R1
R1
R1
R1
R1
R1
R2
R2
R3
R3
R3
R4
R4
R4
R5
R5
R6
R7
R7
R8
R8
R9
R9
R9
R2
R2
R2
R2
R2
R2
R3
R3
R3
R5
R5
R5
R5
R7
R7
R8
R9
R9
R9