Diagnostics

The Diagnostics function of the remote SmartHub allows for easy system troubleshooting. Within this function, the
user can monitor the SmartHub's internal voltages as well as check the firmware version.
Use the Input Dial
Menu: Link Monitor
Menu: System Monitor
Menu: Revision
Menu: PowerUp Detect Displays the number of detected stations,
Menu: Stations Alarms
Menu: Station Last On
Menu: Sensor Monitor
Menu: VA Monitor
34
to navigate through the menus while in the Menu: field.
Allows user to monitor communication
network traffic.
Allows user to monitor all the SmartHubs in
the system.
Displays the SmartHub firmware version and
creation date.
Scroll down to view the motherboard firmware
version as well.
number of detected sensors. It will also display
the date and time of the last power-down (PD)
and last power-up (PU). Press the Down arrow
to scroll down the informations.
Displays any alarms generated by
communication failures between the TM and
any of its stations.
Displays the time, date, current, and voltage of
the last activated station.
Displays real-time sensor information for all
enabled sensors.
Scroll down to review Rain Today, Rain
Yesterday, and Rain Window amounts.
Allows user to monitor the SmartHub's
amperage, voltages and temperature
in real-time. This would be used when
troubleshooting the SmartHub's internal circuit
voltages.
Menu: Link Monitor
Naks: 000 Msg#: 000
FE:
000 Other:000
Menu: Revision
Revision: 2.01p09
Rev Date: 10/9/19
GWY FL Ver 1.0 10/04/12
TM Hardware Ver: 1
Menu: PowerUp Detect
DC 2/500 DB[1,1,0,0]
PD 01/11/19 14:22:20
PU 01/12/19 09:57:24
I2C Events : 000 000
Reset Type : 09
Wire line found: No
Radio Anlg Enbl: No
Menu: Sensor Monitor
Hub Sensors
Inpt 1 Flow: 98.15gpm
Inpt 2 Rain: 00.20in
Inpt 3 Stat: CLOSED
Menu: VA Monitor
Battery:
3.2V
LCD: 27C
VL:-3.5V