3.5.6
8/16 mA electronics cassette
Figure 3-6: 8/16 mA Output (Dark Blue Label)
A. A certified intrinsically safe isolating amplifier to IEC 60947-5-6
Note
This cassette is suitable for Intrinsically Safe (IS) applications and requires
a certified isolating barrier. See the Rosemount 2130
Certifications document
This electronics cassette is also suitable for non-hazardous (safe) area
applications. It can only be interchanged with the NAMUR cassette.
Do not exceed 8 Vdc.
Quick Start Guide
Isolate supply before making connections.
1 2 3
for Intrinsically Safe approvals.
Quick Start Guide
(-)
1
2
PE
(Ground)
-
U
= 24 Vdc Nominal
I
= 15 - 17 mA
ON
I
= 7.5 - 8.5 mA
OFF
I
< 3.7 mA
FAULT