Fiber Optic Ethernet Port Specifications - Siemens SIMATIC NET RUGGEDCOM RS416 Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

Technical Specifications
5.4 Fiber Optic Ethernet Port Specifications
Maximum Distance
Isolation
a
Auto-negotiating.
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.4

Fiber Optic Ethernet Port Specifications

The following details specifications for the fiber optic Ethernet ports that can be
equipped on the RUGGEDCOM RS416.
10Base-FL Ethernet Optical Ports
Connector
Mode
Type
MM
ST
a
Typical.
Fast Ethernet (100 Mbps) Optical Ports
Connector
Mode
Type
MM
ST
MM
SC
MM
MTRJ
SM
ST
SM
SC
SM
LC
SM
LC
SM
SC
SM
LC
SM
SC
SM
LC
a
Typical.
32
d
100 m (328 ft)
e
1.5 kV
Cable
Tx λ
a
Type (µm)
(nm)
62.5/125
850
50/125
Cable
Tx λ
a
Type (μm)
(nm)
62.5/125
1300
50/125
62.5/125
1300
50/125
62.5/125
1300
50/125
9/125
1300
9/125
1300
9/125
1300
9/125
1300
9/125
1300
9/125
1300
9/125
1300
9/125
1300
Tx Min.
Tx Max.
Sensitivity
(dBm)
(dBm)
-16
-9
-19.8
-12.8
Tx Min.
Tx Max.
Sensitivity
(dBm)
(dBm)
-19
-14
-22.5
-19
-14
-22.5
-19
-14
-22.5
-15
-8
-15
-8
-15
-8
-15
-8
-5
0
-5
0
0
5
0
5
Rx
Rx
Distance
Saturation
(km)
(dBm)
(dBm)
-34
-11.2
Rx
Rx
Distance
Saturation
(km)
(dBm)
(dBm)
-31
-14
-31
-14
-31
-14
-32
-3
-31
-7
-34
-7
-34
-7
-34
-3
-35
3
-37
0
-37
0
Installation Manual, 04/2021, C79000-G8976-1018-10
Power
Budget
a
(dB)
18
2
14.2
Power
Budget
a
(dB)
12
2
8.5
12
2
8.5
12
2
8.5
20
17
20
16
20
19
20
19
50
29
50
30
90
37
90
37
RUGGEDCOM RS416

Advertisement

Table of Contents
loading