Connecting Multiple Rs485 Devices - Siemens SIMATIC NET RUGGEDCOM RS416 Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

4.5

Connecting Multiple RS485 Devices

Each RS485 port can communicate with multiple RS485 devices by wiring devices
together in sequence over a single twisted pair with transmit and receive signals on
the same two wires (half duplex). For reliable, continuous communication, adhere to
the following guidelines:
The following shows the recommended RS485 wiring.
2
1
1
2
3
4
5
RUGGEDCOM RS416
Installation Manual, 04/2021, C79000-G8976-1018-10
Red – Error
Off – No signal detected
To minimize the effects of ambient electrical noise, use shielded cabling.
The correct polarity must be observed throughout a single sequence or ring.
The number of devices wired should not exceed 32, and total distance should be
less than 1219 m (4000 ft) at 100 kbps.
The Common terminals should be connected to the common wire inside the
shield.
The shield should be connected to earth ground at a single point to avoid loop
currents.
The twisted pair should be terminated at each end of the chain.
3
4
RUGGEDCOM RS416
Common (Isolated Ground)
Negative
Positive
Shield to Earth (Connected At a Single Point)
4.5 Connecting Multiple RS485 Devices
5
5
120Ω 10nF
120Ω 10nF
Communication Ports
6
29

Advertisement

Table of Contents
loading