Cb70 Status Leds; Battery Charging Recommendations - Danfoss IK3 User Manual

Remote controls
Hide thumbs Also See for IK3:
Table of Contents

Advertisement

User Manual
Remote Control IK3 Transmitters
Charger and battery

CB70 status LEDs

Battery Charging Recommendations

©
Danfoss | May 2021
2. Place the batteries in the compartments of the battery charger.
3. Optional: If charging multiple batteries, wait at least 5 seconds before placing the second battery in
the other compartment.
Possible damage to battery!
Be sure to charge batteries in environments with temperatures over 0° C.
Each battery compartment has an LED that indicates the status of the batteries' charge.
Green LED; pulsing
Green LED; continuous
Green LED; off
The battery charger must be placed and used out of the danger area.
The battery lifespan is estimated to 500 recharging cycles and is largely dependent on the conditions of
use. To maximize the lifespan of the batteries and battery charger, follow these recommendations:
Do not recharge the battery until it is completely flat, as shown with red LED slow pulse on the
transmitter
Always charge the batteries at temperatures between 0° and 45°C (the batteries will not become fully
charged at temperatures exceeding 45°C)
Do not leave the battery charger or batteries in a direct sunlight
Charge batteries at least once every six months
Avoid short circuits between the battery contacts; do not carry charged batteries in toolboxes or next
to other metal objects (keys, coins, etc.)
Always keep contacts clean
Caution! Risk of Explosion if Battery is Replaced by an incorrrect type. Non Danfoss Battery use may
void warranty
Battery is excessively depleted
Normal charging operation mode
Battery charging process is complete
BC290857689420en-000201 | 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents