Remote Control IK3 Transmitters
Technical description
8 |
©
Danfoss | May 2021
Start up the device
1. Place a charged battery in the transmitter.
The battery must be charged following the instructions of the Battery Charger Manual.
2. Turn the contact key or Multikey to the position "I." It is not necessary to switch the contact key off
after use, however, it may be removed in order to deny access to the transmitter.
3. Push and pull out the STOP button.
LED status (blue)
LED will flash, blinking blue until it reaches the Stand-by mode (fixed blue). If the transmitter includes
a Display, it will display the identification of the machine, as well as the battery level, if it has been
pre-programmed.
4. Press the START button, and wait for the status LED to turn to fixed green.
LED status (green)
The status LED will start blinking green, meaning the transmitter is trying to connect with the
receiver. Once the Tx is linked, LED will turn to fixed green.
5. Press any of the transmitter's maneuver buttons and its corresponding relay will be activated.
6. Check to make sure all the maneuvers work in a coherent way with the expected movements by
checking the supplied production sheet, included with the system.