Danfoss IK3 User Manual page 11

Remote controls
Hide thumbs Also See for IK3:
Table of Contents

Advertisement

User Manual
Remote Control IK3 Transmitters
Maintenance
LED color | Frequency
Pulse Frequency
Green / fast pulses
Green | continuous
Green | slow pulses
Red | slow pulses
Red | double pulses
Red | continuous
Orange | slow pulses
Orange | double pulses
©
Danfoss | May 2021
Description
Trying to link with the receiver and waiting its
answer.
The transmitter works properly. Operation
mode is OK.
STANDBY mode. If transmitter is 4 minutes
ON and no action has been taken.
EEPROM Error. EEPROM module is missing or
corrupted.
Radio Error. Radio communication error.
Hardware failure or damage.
Battery signal is critical.
A maneuver is activated.
Action
Wait
No action needed.
Press START to return to Operation mode.
Check EEPROM module or reprogram if
necessary.
Replace transmitter
Replace transmitter
Replace batteries with charged ones.
Release maneuver or replace transmitter if
necessary.
BC290857689420en-000201 | 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents