Maintenance; Maintenance Tips; Troubleshooting 400-900 Mhz; Troubleshooting 2.4 Ghz - Danfoss IK3 User Manual

Remote controls
Hide thumbs Also See for IK3:
Table of Contents

Advertisement

User Manual
Remote Control IK3 Transmitters

Maintenance

IK3 maintenance tips
Maintenance tips quick reference
Troubleshooting (400-900 MHz)
Color and frequency
Pulse frequency
Green | continuous
Green | slow pulses
Red | slow pulses
Red | fast pulses
Red | double pulses
Red | continuous

Troubleshooting 2.4 GHz

LED color | Frequency
Pulse Frequency
Blue / fast pulses
Blue | continuous
10 |
©
Danfoss | May 2021
This product is designed for use in an industrial environment that may shorten the product's lifespan. Use
these tips to maximize the lifespan of the product.
Use the hook/belt provided with the transmitter to prevent the transmitter from falling
Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for
cleaning
If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair
Check if the battery contacts are correct, otherwise replace them.
Ensure that the product is supplied with AAA alkaline batteries or has a rechargeable battery
Be sure to recharge or replace battery regularly
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are contained in the table below:
Description
Working
Latency; no action has been taken for some time
Low battery signal
EEPROM module missing or corrupt
A maneuver is activated at transmitter start up process;
may indicate hardware damage if no order is active
General hardware failure
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are in the table below:
Description
Starting the system,establishing
communication with radio and EEPROM.
Stand-by. Set up system, waiting user's action. Press START to enter Operation mode.
Action
Operate
Press START to return to operation
mode
Replace or recharge battery
Check EEPROM and reprogram if
necessary
Release maneuver or replace
transmitter if necessary
Replace transmitter
Action
Wait
BC290857689420en-000201