Danfoss IK3 User Manual

Danfoss IK3 User Manual

Remote controls
Hide thumbs Also See for IK3:

Advertisement

User Manual
Remote Controls
IK3 Transmitters
www.danfoss.com

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss IK3

  • Page 1 User Manual Remote Controls IK3 Transmitters www.danfoss.com...
  • Page 2 User Manual Remote Control IK3 Transmitters Revision history Table of revisions Date Changed May 2021 Added trouble shooting and start-up information for TR2400 0201 February 2019 Rebranded to Danfoss Power Solutions 0101 © Danfoss | May 2021 BC290857689420en-000201...
  • Page 3: Table Of Contents

    User Manual Remote Control IK3 Transmitters Contents Safety instructions FCC rules......................................4 General safety....................................4 Safety warnings....................................5 Technical description Dimensions and identification..............................6 IK Transmitters Start up (400-900Mhz)............................. 7 IK Transmitters Start up (2.4 GHz)...............................7 IK3 Detailed description.................................9 Maintenance Maintenance tips....................................10 Troubleshooting 400-900 MHz..............................
  • Page 4: Safety Instructions

    • Service the equipment periodically. • When carrying out repairs, use spare parts supplied by Danfoss only. Warning Potential damage to the operator or the product. Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX/RATEX certified to work in such conditions.
  • Page 5: Safety Warnings

    Avoid knocking or dropping the product. • Do not use the product if a failure is detected. Changes or modifications not approved by Danfoss can void the user's authority to operate this product. Quick reference precautions © Danfoss | May 2021...
  • Page 6: Technical Description

    User Manual Remote Control IK3 Transmitters Technical description IK3 dimensions and identification The illustration below details dimensions and features of the IK3 transmitter. Dimensions in mm 181.16 Label for crane identification Maneuver elements Contact key Start push button STOP button...
  • Page 7: Ik Transmitters Start Up (400-900Mhz)

    User Manual Remote Control IK3 Transmitters Technical description IK Transmitters Start up (400-900Mhz) Use the information below to properly turn the transmitter ON (OPERATION mode). 1. Place a charged battery in the transmitter. The charge must be done following the instructions of the Battery Chargers' Manual.
  • Page 8 User Manual Remote Control IK3 Transmitters Technical description Start up the device 1. Place a charged battery in the transmitter. The battery must be charged following the instructions of the Battery Charger Manual. 2. Turn the contact key or Multikey to the position "I." It is not necessary to switch the contact key off after use, however, it may be removed in order to deny access to the transmitter.
  • Page 9: Ik3 Detailed Description

    User Manual Remote Control IK3 Transmitters Technical description IK3 Detailed description Description Value Stop function (400 - 900 MHz) Cat. 3-PLd Stop Function (2.4 GHz) Cat3 - PLe Ingress Protection rating IP65/NEMA4 Anti-condensation system Goretex Film Frequency band - ERP 433.050 to 434.040 MHz;...
  • Page 10: Maintenance

    User Manual Remote Control IK3 Transmitters Maintenance IK3 maintenance tips This product is designed for use in an industrial environment that may shorten the product's lifespan. Use these tips to maximize the lifespan of the product. • Use the hook/belt provided with the transmitter to prevent the transmitter from falling •...
  • Page 11 User Manual Remote Control IK3 Transmitters Maintenance LED color | Frequency Pulse Frequency Description Action Trying to link with the receiver and waiting its Wait Green / fast pulses answer. The transmitter works properly. Operation No action needed. Green | continuous mode is OK.
  • Page 12: Charger And Battery

    User Manual Remote Control IK3 Transmitters Charger and battery Charger and battery Disposal note: This symbol on the product indicates that it may not be disposed of as household waste. It must be handed over to the applicable take-back scheme for the recycling of electrical equipment.
  • Page 13: Cb70 Status Leds

    (keys, coins, etc.) • Always keep contacts clean • Caution! Risk of Explosion if Battery is Replaced by an incorrrect type. Non Danfoss Battery use may void warranty © Danfoss | May 2021 BC290857689420en-000201 | 13...
  • Page 14: Cb70 Battery Charger Dimensions

    User Manual Remote Control IK3 Transmitters Charger and battery CB70 battery charger dimensions Dimensions in mm 131.60 34.50 14 | © Danfoss | May 2021 BC290857689420en-000201...
  • Page 15 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

Table of Contents