Warning Code List - Sony CLX101ASA Service Manual

Display unit
Table of Contents

Advertisement

3-3-5. Warning Code List

DCS: Display Control Software
CAS: Color Uniformity Alignment Software
:
Port number (1 to C)
:
Display unit number (0 to 7)
Category
Code on DCS
Temperature/Fan
310
313
-
-
313
313
11
Front view
1
2
5
6
9
0
-
-
313
31
CLX101ASA
Code on CAS
_
310-
-11
310-
-12
_
313-
-11
-
-
14
313-
-12
3
4
7
8
!-
!=
313-
-13
-
-
313
34
313-
-14
Symptom/Cause/Remedy
Symptom/Cause: An abnormality was detected in the temperature
sensor of the display unit.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
Symptom/Cause: An abnormality was detected in the board tempera-
ture sensor of the display unit.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
Symptom/Cause: An abnormality was detected in the ambient
temperature sensor of the display unit.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
Symptom/Cause: The temperature of cell (1 to 12) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the cell.
Symptom/Cause: Temperature of the cell of 1 shown in the figure on
the left (in the top line, and first from the left viewed
from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 2 shown in the figure on
the left (in the top line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 3 shown in the figure on
the left (in the top line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 4 shown in the figure on
the left (in the top line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.