Error Code List - Sony CLX101ASA Service Manual

Display unit
Table of Contents

Advertisement

3-3-4. Error Code List

DCS: Display Control Software
CAS: Color Uniformity Alignment Software
:
Port number (1 to C)
:
Display unit number (0 to 7)
Category
Code on DCS
Temperature
017
Power
104
Temperature
110
111
113
113
-
-
113
11
Front view
1
2
5
6
9
0
-
-
113
31
3-12 (E)
Code on CAS
017-00-00
104-
-00
110-
-00
111-
-00
_
113-
-11
-
-
14
113-
-12
3
4
7
8
!-
!=
113-
-13
113-
-14
-
-
113
34
Symptom/Cause/Remedy
Symptom/Cause: The temperature of display unit (cell 1 to cell 12) is
abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the cell.
Symptom/Cause: The power block is defective.
Remedy: Replace the PS-903 board.
Symptom/Cause: An abnormality was detected in the temperature
sensor of the display unit.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
Symptom/Cause: An abnormality was detected in the temperature
sensor on the UC-1 board.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature of the operating environment.
. Replace the fan.
. Replace the UC-1 board.
Symptom/Cause: The temperature of cell (1 to 12) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the cell.
Symptom/Cause: Temperature of the cell of 1 shown in the figure on
the left (in the top line, and first from the left viewed
from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 2 shown in the figure on
the left (in the top line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 3 shown in the figure on
the left (in the top line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 4 shown in the figure on
the left (in the top line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.