Required items
Part No.
Name
_
Cell assembly (RP)
. Cell assembly
. Flexible flat cable (TOP)
. Flexible flat cable (MID)
. Flexible flat cable (BTM)
. X shim
(*)
. Y shim
(*)
. Z shim (t0.04)
. Z shim (t0.08)
. Z shim (t0.12)
. Z shim (t0.20)
. USB memory
J-6252-520-A
Torque driver (12 kg.cm)
(1.2 N.m)
J-6252-540-B
Torque driver bit set
. Hexagonal bit (subtense: 2)
. Hexagonal bit (subtense: 2.5)
. Hexagonal bit (subtense: 3)
. Bit for +2 mm
. Bit for +2.6 mm
. Bit for +3 mm
X-2593-980-1
Guide pin
4-689-815-01
FFC remover
_
Color Uniformity Alignment Soft-
ware
_
Fall prevention tape (T4082S
made by Dexerials is recom-
mended)
_
Digital caliper (Resolution: 0.01
mm or less)
(*) If you lose a shim, you can purchase shims only what you require.
Name
Part No.
X shim
X-2595-452-1
Y shim
X-2595-453-1
Z shim (t0.04)
X-2595-454-1
Z shim (t0.08)
X-2595-455-1
Z shim (t0.12)
X-2595-456-1
Z shim (t0.20)
X-2595-457-1
4-22 (E)
No. of pcs
1
1
1
1
1
2
2
(*)
6
(*)
6
(*)
6
(*)
18
1
1
1
2
1
_
4
1
No. of pcs
One set with two pieces
One set with two pieces
One set with six pieces
One set with six pieces
One set with six pieces
One set with six pieces
Usage in cell assembly replacement/Remarks
For obtaining a cell assembly (RP), contact your
local Sony Service Center.
n
When replacing the cell assembly, use the
packing materials. Do not discard the packing
materials.
Protection for cell assembly and clearance
control
Thickness control in the Z direction
Data of cell assembly (RP)
Tightening for M3 (+) screws
Tightening torque
. For cell assembly: 8 kg.cm (0.8 ?0.1 N.m)
. Except for cell assembly: 6 kg.cm
(0.6 ?0.1 N.m)
Tightening for M3 (+) screws
Guide and support for cell assembly
Two guide pins are required for cell assembly
replacement.
Removing the flexible flat cable on UC-1 board
Writing the data
For obtaining Color Uniformity Alignment Soft-
ware, contact your local Sony Service Center.
Attaching cell assembly temporally
The four tapes with 80 mm length are required.
Measuring the thickness of cell assembly
CLX101ASA