Technical Data - Ecoflam MAIOR P 700.1 PRE Manual

Light oil burners
Table of Contents

Advertisement

EN
TECHNICAL DATA
MODEL
Thermal power max.
Thermal power min.
Operation mode
Regulation ratio nominal
Fuel
Emission class
Control unit
Air regulation
Air flap control with servomotor
Air pressure switch
Flame monitoring
Ignitier
Motor
Rpm
Voltage
Total power consumption operation
Weight body BBCH
Electrical panel protection level
Sound pressure level
without silencer
Sound pressure level
with silencer
Ambient temperature storage
Ambient temperature use
Oil pump
Oil pump motor
Nozzles
6
www.ecoflam­burners.com
MAIOR P 700.1
kW
7.500
kcal/h
6.465.000
kg/h
634
kW
2.417
kcal/h
2.096.000
205
kg/h
Type
Type
Light oil (L.C.V. 10.200 kcal/kg max. visc 1,5°E at 20°C) - EL) Hu = 11,86 kWh/kg
Type
std
Type
Air flap
Type
Model
mbar
N/A
Type
Model
kW
15
2.800
V/Hz
16.500
W
Kg
IP40
IP
94,1
dB(A)
Lab
tests
86,9
Min/Ma
x
Model
TA5
kW
1,5 kW
Type
MAIOR P 800.1
MAIOR P 1000.1
8.500
7.328.000
718
2.750
2.385.000
234
Progressive electronic oil - Modulating with PID
1÷3 OIL
Standard Class 1 OIL EN267 (<250 mg/kWh)
LAMTEC BT 320
Air flap
LAMTEC
2,5...50 mbar
photoresistor
BRAHMA
18,5
2.800
230/400 V - 50 Hz
20.000
IP40
94,6
87,8
-20°...+70° C
-10°...+60° C
TA5
1,5 kW
according to the output requested
MAIOR P 1200.1
10.500
12.500
9.052.000
10.776.000
887
1.053
3.300
4.367
2.862.000
3.788.000
281
371
Air flap
Air flap
22
37
2.800
2.800
28.000
41.000
IP40
IP40
95,6
96,3
88,1
88,9
T5+TV
T5+TV
5,5 kW
5,5 kW
420010985900

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maior p 800.1 preMaior p 1000.1 preMaior p 1200.1 pre

Table of Contents