8.1.3 Common substances

8.2 Requirements of container and Installation Instruction

1. Could either glue the probe or use a support to fix the probe on the outside of the container.
2. Avoid metal materials at the probe mounting site so as not to affect the detection.
3. The place where the probe is installed should avoid the liquid and the flow path of the liquid.
4. There should be no silt or other debris inside the container where the low-level probe is directly facing, so as not to affect the detection.
Containers made of non-metallic materials with flat surface, uniform thickness, tight material and good insulation performance; such as glass,
5.
plastic, non-absorbent ceramic, acrylic, rubber and other materials or their composite materials.
Induction sheet clings to water pipe
Sensitivity adjustment knob
Substance
Viscosity (mPa·s)
Benzene
Water
Mercury
Whole milk
Olive oil
Reference source: https://en.wikipedia.org/wiki/Viscosity
R718VB
Temperature (°C)
0.604
1.0016
1.526
2.12
56.2
9
25
20
25
20
26
The induced liquid level height is related to the
sensitivity of the sensor.
The higher the sensitivity, the lower the
induced liquid level.
Note:
The liquid level is sensed in the upper and lower
edges of the sensing film, which is normal.