Performance Charts - Graco Viscount High-Flo Plus 25E933 Instructions-Parts List Manual

Table of Contents

Advertisement

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a spe-
cific fluid flow (lpm/gpm) and operating hydraulic pres-
sure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve (black). Follow left to
scale to read fluid outlet pressure.
See Models on page 3 for your pump part number.
Key:
A
10.3 MPa, 103 bar (1500 psi)
hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi)
hydraulic pressure
C
4.1 MPa, 41 bar (600 psi)
hydraulic pressure
Fluid outlet pressure
Hydraulic oil consumption
3A6939B
To find Motor Hydraulic Oil Consumption (l/min. or
gpm) at a specific fluid flow (l/min. or gpm):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with hydraulic oil
consumption curve (dashes). Follow right to scale to
read hydraulic oil consumption.
Viscount II Motor, 2500cc Lower
0
2
4
500
(34.8,3.48)
450
(31.0,3.10)
400
(27.6,2.76)
350
(24.1,2.41)
300
(20.7,2.07)
250
(17.2,1.72)
200
(13.8,1.38)
150
(10.3,1.03)
100
(6.9,0.69)
50
(3.4,0.34)
0
0
1
2
3
(3.8)
(7.6)
(11.4)
FLUID FLOW, gpm (lpm)
CYCLES PER MIN.
6
8
10
12
A
C
4
5
6
7
8
(15.1)
(18.9)
(22.7)
(26.5)
(30.3)
Performance Charts
14
16
6
(22.7)
5
(18.9)
4
(15.1)
3
(11.4)
2
(7.6)
1
(3.8)
0
9
10
(34.1)
(37.9)
17

Advertisement

Table of Contents
loading