Technical Data; Standards And Operating Conditions; Conformities And Approvals; Protection Of Persons And Device Protection - Lenze MCA Series Mounting And Switch-On Instructions

Asynchronous servo motors
Table of Contents

Advertisement

Available languages

Available languages

Technical data

Standards and operating conditions

Conformities and approvals

Technical data
Standards and operating conditions
Conformities and approvals
Conformity
CE
EAC
Approval
cURus
UkrSepro

Protection of persons and device protection

Degree of protection
IP23S
IP54
IP65
Temperature class
F (155 °C)
Max. voltage load
Limit curve A
IVIC C/B/B@500V

EMC data

Noise emission
Noise immunity

Environmental conditions

Climate
1K3 (-20 °C ... +60 °C)
1K3 (-20 °C ... +40 °C)
2K3 (-20 °C ... +70 °C)
3K3 (-20 °C ... +40 °C)
3K3 (-15 °C ... +40 °C)
3K3 (-10 °C ... +40 °C)
Relative humidity≤ 85 %
Site altitude
0 ... 1000 m amsl
1000 ... 4000 m amsl
Vibration resistance
3M6
Vibration severity
A
B
Vibration velocity (free suspension)
1.6 mm/s
0.7 mm/s
Smooth running, axial runout, concentricity
Normal class
Precision class
70
2014/35/EU
Low-Voltage Directive
2014/30/EU
EMC Directive (reference: CE-typical drive system)
TR TC 004/2011
Eurasian conformity: safety of low voltage equipment
TP TC 020/2011
Eurasian conformity: electromagnetic compatibility of technical
means
UL 1004-1
for USA and Canada (requirements of the CSA 22.2 No.100)
UL 1004-6
Industrial Control Equipment, Lenze File No. E210321
for Ukraine
EN 60034-5
Forced ventilated: MCA20, MCA22, MCA26
EN 60034-5
Self-ventilated: MCA10 ... MCA19, MCA21
Forced-ventilated: MCA13 ... MCA19, MCA21 ... MCA26
EN 60034-5
Self-ventilated: MCA10 ... MCA19, MCA21
EN 60034-1
IEC/TS 60034-25:2007
IEC 60034-18-41
EN 60034-1
A final overall assessment of the drive system is indispensable
EN 60034-1
A final overall assessment of the drive system is indispensable
EN 60721-3-1
Storage, < 3 months
EN 60721-3-1
Storage, > 3 months
EN 60721-3-2
Transport
EN 60721-3-3
Operation, without brake, self-ventilated
EN 60721-3-3
Operation, without brake, forced ventilated
EN 60721-3-3
Operation, with brake
Without condensation
Without power reduction
Observe the power reductions of the inverter and the servo motor
EN 60721-3-3
Operation
EN 60034-14
MCA10, MCA13, MCA20, MCA22, MCA26
EN 60034-14
MCA14, MCA17, MCA19, MCA21
MCA10, MCA13, MCA20, MCA22, MCA26
MCA14, MCA17, MCA19, MCA21
IEC 60072
MCA10, MCA13, MCA20, MCA22, MCA26
IEC 60072
MCA14, MCA17, MCA19, MCA21

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents