Wi-Fi device IE-WL-VL-AP-BR-CL

DI and Power Status

The status of power inputs and digital inputs is shown on this web page. The status will refresh every 5 seconds
if the Auto refresh box is checked.

AeroLink Protection Status (For Client/Slave Mode Only)

After you have enabled AeroLink Protection in the Advanced WLAN Setup panel, the current state of the
AeroLink Protection is displayed here for easy diagnosis.
A member of the AeroLink Protection group can take one of the following seven states:
Initiation State (Init): Initiates the AeroLink Protection Protocol
Discovering State (Discover): Discovers other AeroLink Protection members for further negotiation
Idle State (Idle): Internal protocol checkpoint
Negotiation State (Nego): Negotiates with other AeroLink Protection members and elects an Active
node.
Backup State (Backup): After negotiation, this node is assigned as a Backup node. All traffic will go
through the Active node instead.
NOTE
When a node is in Backup state, the STATE LED will be blinking.
Active State (Active): After negotiation, this node is assigned as Active node, which means that all traffic
will go through this node.
Role Change State (Change): If the Active node is no longer capable of data transmission via the WLAN,
it will turn into Change State to trigger the re-negotiation of the Active node from the Backup nodes.