Wi-Fi device IE-WL-VL-AP-BR-CL

Beeper

The beeper emits two short beeps when the system is ready.

Reset Button

The RESET button is located on the top panel of the IE-WL-VL-AP-BR-CL. You can reboot the device or reset it
to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip.
System reboot: Hold the RESET button down for under 5 seconds and then release.
Reset to factory default: Hold the RESET button down for over 5 seconds until the STATE LED starts
blinking green. Release the button to reset the IE-WL-VL-AP-BR-CL.

Relay (Digital Output)

The IE-WL-VL-AP-BR-CL has one relay output consisting of the 2 terminal block contacts on the top panel, as
shown below. These relay contacts are used to forward system failures and user-configured events.
The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If
a user-configured event does not occur, the relay circuit will remain closed. For safety reasons, the relay circuit
is kept open when the IE-WL-VL-AP-BR-CL is not powered up.
Summary of the IE-WL-VL-AP-BR-CL's Relay Status
Power Status
Off
On
Event
Relay
Open
Yes
Open
No
Short
1-8