To simplify the adjustment, the AMS uses Reference Letter designators that correspond to the following TOF
mark distances:
Reference
Position the Adjustable Media Sensor as follows:
1. Based on the measurement made earlier, choose the Reference Letter that best corresponds to the
location of your TOF mark.
2. Use a finger to move the Bottom Slide until your selected Reference Letter appears in the Setting Window
of the slide.
3. Use a finger to move the Top Slide until your selected Reference Letter appears in the Setting Window of
the slide.
The Top and Bottom Slides must be positioned over the same Reference Letter for proper media
sensor function.
4. Proceed to 'Loading Media' (Section 2.4).
Chapter 2 – Printer Setup
Distance of the TOF Mark from the Media Edge
Letter
(inches)
A
B
C
D
E
F
G
H
I
J
K
L
Top Slide
Bottom Slide
.180
.500
.750
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
Reference Letters
Setting Window
Setting Window
Reference Letters
(millimeters)
4.6
12.7
19.1
25.4
31.8
38.1
44.5
50.8
57.2
63.5
69.9
76.2