P4-30...L100-11 Model: E12a Assembly and Operating Instructions Tubular drives for sun protection systems Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2010 301 096 0 14/08/2018 ...
Table of contents General .................................... 3 Warranty ..................................... 3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable .......................... 6 Disassembling the plug-in connecting cable for tubular drives dia.
General These tubular drives are high-quality products with the following features: • Optimised for sun protection applications • Installation without stops is also possible (from extended point to retracted point) • Automatic detection of limit positions thanks to intelligent electronic system with stop systems •...
Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
Page 5
• Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any other surface from which the drive can be accessed. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
Intended use The type of tubular drive described in these instructions is intended solely for the operation of awnings, cassette awnings, screens, drop-arm awnings and conservatory shades. It may only be used in networked systems if all the individual drives are exactly synchronised and reach the limit positions at the same time.
Disassembling the plug-in connecting cable for tubular drives dia. 35. Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug.
Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
Disassembling the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool, Item no. 4930 300 606 0 Disassembly with long nose pliers Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Mounting the drive in the tube For profile tubes: In the case of some drive adapters, tolerances of the groove widths in different bar-...
Page 11
For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft. To ensure secure torque transmission for round shafts, we recommend screwing the drive adapter to the shaft (see the table below).
Setting the limit positions with the switches on the drive head Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
Page 13
Extended point to retracted point There is no shading solution length adjustment with this limit position setting. Set both switches to the delete setting. Execute a short drive command. Open to the desired extended limit position. Change the setting of the extending direction of rotation switch from the delete set- ting to the programming setting.
Deleting the limit positions with the switches Deleting individual limit positions It is only possible to delete an individual limit position if the extended point to retracted point was programmed with the switches. Any additional functions that have been set are retained.
Adjusting the limit positions with a rotary switch or a locking button Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
Extended point to retracted stop Set both switches to the programming setting. Open to the desired extended limit position. Carry out the following sequence without interruption between the individual drive commands. ▻ The tubular drive confirms. until STOP and hold until Then retract to the permanent upper stop.
Setting the limit positions using the programming unit Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
Page 18
Extended point to retracted point with programming unit There is no shading solution length adjustment with this limit position setting. Set both switches to the programming setting. Open to the desired extended limit position. Press the programming button of the programming unit for 3 seconds. ▻...
Changing the additional stop behaviour function with the programming unit On delivery, the 35 diameter drive types have a reduced stop behaviour, and the 45 diameter and 58 diameter drive types have an increased stop behaviour. Proceed as follows to change the stop behaviour: The "to retracted stop"...
Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
Page 21
Deleting both limit positions Any additional functions that may have been set are deleted at the same time, or are reset to the factory default settings. Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed.
Setting the limit positions with Auto-Install Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
Auto point to retracted stop (only with articulated-arm awnings) Attention Ensure that the cloth is not wound up the wrong way by the barrel. Extend Retract Set both switches to the programming setting. Extend the articulated-arm awning until the articulated arms are fully protracted and the cloth is lying loosely over them.
Activating/deactivating the additional fabric untensioning function with the programming unit The "to retracted stop" limit position must be set for the fabric untensioning function. On delivery, the fabric tensioning function is deactivated. To activate/deactivate it, move to the Retract limit position. Press the programming button for approx.
The packaging material must be disposed of properly. Maintenance These drives are maintenance-free. Technical data dia. 35 Tubular drive P4-30 Model E12a Type C PS V1 A Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage...
Technical data dia. 45 Tubular drive R12-17 R30-17 R40-17 R50-11 Model E12a Type C PS+ V1 A Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 240 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.50...
What to do if...? Problem Remedy Tubular drive overruns the limit position or does not reach the Repair electrical installation and re-program limit positions. set limit position. Check electrical installation; remove external devices; reset limit positions. Stops have broken off or one or several attachments are broken.
Need help?