Pilz PSEN ma1.4-51 M12/8-0.15m Operating Manual

Pilz PSEN ma1.4-51 M12/8-0.15m Operating Manual

Psen sensor technology
Hide thumbs Also See for PSEN ma1.4-51 M12/8-0.15m:

Advertisement

Quick Links

PSEN ma1.4-51 M12/8-0.15m
PSEN sensor technology
}
Operating Manual-22185-EN-05

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PSEN ma1.4-51 M12/8-0.15m

  • Page 1 PSEN ma1.4-51 M12/8-0.15m PSEN sensor technology Operating Manual-22185-EN-05...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Pin assignment Requirements and connection to evaluation devices Installation Installation type 1 Installation type 2 Adjustment Periodic test Dimensions in mm Technical details Safety characteristic data Order reference System Accessories EC declaration of conformity Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 4: Introduction

    PSEN ma1.4-51 M12/8-0.15m Introduction Validity of documentation This documentation is valid for the product PSEN ma1.4-51 M12/8-0.15m. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    In order to achieve the re- quired safety level for the overall plant/machine, define the safety requirements for the plant/machine and then define how these must be implemented from a technical and organ- isational standpoint. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 6: Use Of Qualified Personnel

    – If spare actuators are used, these must be installed as described in Installation [ 13]. – If the original actuators are replaced with substitute actuators, the ori- ginal actuators must be destroyed before disposal. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 7: Unit Features

    If the actuator is within the response range (safety gate closed), the safety contacts and the auxiliary contact on the safety switch will be closed and the LED will light. Operate the PSEN ma1.4-51 M12/8-0.15m in conjunction with the following components: Actuator PSEN ma1.4-03 or actuator PSEN ma1.4-10 (see...
  • Page 8: Operating Distances

    Lateral and vertical offset Legend [1] Lateral offset [2] Vertical offset Actuator PSEN ma1.4-03 Assured operating distance S in mm Lateral offset Vertical offset The stated values are valid at a temperature of 20 °C. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 9: Wiring

    Pin assignment NOTICE The colour marking for the connection lead only applies for the cable that Pilz supplies as an accessory The safety switch is shown in an unoperated condition. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 10: Requirements And Connection To Evaluation Devices

    PNOZmulti units – may not be used for safety circuits Requirements and connection to evaluation devices For use of PSEN ma1.4-51 M12/8-0.15m in accordance with DIN EN 60947-5-3 an evalu- ation device must be connected. Connect the PSEN ma1.4-51 M12/8-0.15m either with a certified Pilz evaluation device...
  • Page 11 17]) and the processing and delay times of the evaluation device (s. operating manual for the relevant evaluation device). PSENmag Evaluation device Input circuit Input circuit Fig.: Dual-channel connection PSEN ma1.4-51 M12/8-0.15m to the input circuits of an evaluation device Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 12 PSEN ma1.4-51 M12/8-0.15m Examples for connection to Pilz evaluation devices: PNOZ s3 PSENmag white green yellow pink PNOZmulti PSENmag white green yellow pink Auxiliary contact with LED The auxiliary contact and the LED indicate the status of the safety contacts.
  • Page 13: Installation

    S can change. – Check the assured release distance S Safety switches and actuators must be positioned so that they are secured against a change of position. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 14 4. Align actuator to sensor. INFORMATION The inscribed area on the actuator (sensing face) should face the sensor. 5. Slide the actuator on to the screws. 6. Align sensor and tighten screws with max. 0,8 Nm. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 15: Installation Type 2

    11. Installation of sensor and actuator is now complete. INFORMATION Seals (1), (2), (3) meet the requirements of UL 94 V0, seal (4) does not meet UL requirements. Installation type 2 Install the sensor as shown for installation type 1 Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 16: Adjustment

    Seals (1), (2), (3) meet the requirements of UL 94 V0, seal (4) does not meet UL requirements. Adjustment The safety switch may only be used with the corresponding actuator PSEN ma1.4-03 or PSEN ma1.4-10. Always test the function with a connected evaluation device. Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 17: Periodic Test

    14,4 26,4 Technical details General 506344 506345 CE, EAC (Eurasian), TÜV, cULus CE, EAC (Eurasian), TÜV, cULus Approvals Listed Listed Sensor's mode of operation Magnetic Magnetic Coding level in accordance with EN ISO 14119 Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 18 Shock stress Acceleration Duration 11 ms 11 ms Airgap creepage Pollution degree Rated insulation voltage 60 V 60 V Rated impulse withstand voltage 0,8 kV 0,8 kV Protection type Housing IP67 IP67 Connector IP67 IP67 Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 19: Safety Characteristic Data

    You must comply with the safety-related characteristic data in order to achieve the required safety level for your plant/machine. B10d in accordance with EN ISO 13849-1: 2015 TM [year] in accordance with EN ISO and EN 62061 13849-1:2015 7.300.000 Operating Manual PSEN ma1.4-51 M12/8-0.15m 22185-EN-05...
  • Page 20: Order Reference

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN ma1.4-51 M12/8-0.15m...
  • Page 21 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...

Table of Contents