1.16 ADAPTOR C9 KIT INSTALLATION.

This kit allows to install an Immergas boiler in
configuration "C93", achieving the combustion
air intake directly from the shaft featuring the
fumes exhaust, obtained by means of a ducting
system.
System composition.
The system must be combined with the following
components (sold separately) to be functional
and complete:
- kit C93 version Ø 100 or Ø125
- ducting kit Ø 60 or Ø 80
- fumes exhaust kit Ø 60/100 or Ø 80/125 con-
figured according to the installation and type
of boiler.
Kit Assembly.
- Mount the components of kit "C9" on the door
(A) of the ducting system (Fig. 1-25).
- (Version Ø 125 only) mount the flanged adap-
tor (11) interposing the concentric gasket (10)
on the boiler, fitting it with the screws (12).
- Mount the ducting system as described in the
relative instructions sheet.
- Calculate the distances between the boiler drain
and the bend of the ducting system.
- Prepare the boiler flue system, making sure that
the internal pipe of the concentric kit is fitted
properly in the bend of the ducting system
(quota "X" fig. 1-26), while the external pipe
must be fitted on the adaptor until it stops (1).
N.B.: to encourage the removal of possible
condensate forming in the exhaust pipe, tilt
the pipes towards the boiler with a minimum
slope of 1.5%.
1-24
A
B
Kit composition:
Ref.
Qty
Description
1
1
Door adaptor Ø 100 or Ø 125
2
1
Door gasket made of neoprene
3
4
Screws 4.2 x 9 AF
4
1
Hex headed screw M6 x 20
5
1
Flat nylon washer M6
6
2
Door hole closure metal-sheet plate
plug
7
1
Plug gasket made of neoprene
8
1
Toothed washer M6
9
1
Nut M6
10
1 (kit 80/125) Concentric gasket Ø 60-100
11
1 (kit 80/125) Flanged adapter Ø 80-125)
12
4 (kit 80/125) Hex headed screws M4 x 16 slotted
-
1 (kit 80/125) Bag of lubricating talc
Supplied separately:
Ref. Qty Description
A
1
Ducting kit door
- Mount the cover (A) complete with adaptor (1)
and caps (6) on the wall and assemble the flue
system to the ducting system.
N.B.: (version Ø 125 only) before assembly check
the gaskets are in the right position. In the event
component lubrication (already carried out
by the manufacturer) is not sufficient, remove
the residual lubricant using a dry cloth, then
to ease fitting coat the parts with common or
industrial talc.
Once all components have been assembled prop-
erly, the exhaust fumes will be expelled via the
ducting system; the combustion air for normal
boiler operation will be aspirated directly by the
shaft (Fig. 1-26).
Technical data.
- The dimensions of the shafts must ensure a
minimum gap between the outer wall of the
smoke duct and the inner wall of the shaft: 30
mm for circular section shafts and 20 mm in
the event of a square section shaft (Fig. 1-24).
- Maximum 2 changes of direction are allowed
on the vertical section of the flue system with
a maximum clearance angle of 30° with respect
to the vertical.
- The maximum vertical extension using a Ø
60 ducting system is 13 m, the maximum
extension includes 1 bend Ø 60/10 at 90°, 1 m
of horizontal pipe 60/100, 1 90° ducted bend
Ø 60 and the roof terminal for ducting.
Rigid Ø 60
ducting (A)
mm
66
A
C
Installation drawings key:
SHAFT
SHAFT
(B) mm
(C) mm
106
126
Unique identification of the component in
1
the kit
Identification of the component not supplied
A
in this kit
3
12
3
12
4
11
10
16
To determine the C93 flue system in configu-
rations other than that described (Fig. 1-26)
one must consider that 1 metre of ducted pipe
according to the indications described has a
resistance factor equal to 4.9.
- The maximum vertical extension using a Ø 80
ducting system is 28 m, the maximum exten-
sion includes 1 adapter 60/100 to 80/125, 1 87°
bend Ø 80/125, 1 m of horizontal pipe 80/125,
1 90° ducted bend Ø 80 and the roof terminal
for ducting.
To determine the C93 flue system in configura-
tions other than that described (Fig. 1-26) one
must consider the following pressure drops:
- 1 m of concentric pipe Ø 80/125 = 1 m of
ducted pipe;
- 1 87° bend = 1.4 m of ducted pipe;
Consequently one must subtract the equivalent
length of the part added to the 28 m available.
Rigid Ø 80
SHAFT
ducting (A)
(B) mm
mm
86
126
Flexible Ø 80
SHAFT
ducting (A)
(B) mm
mm
90
130
2
1
3
7
6
5
SHAFT
(C) mm
146
SHAFT
(C) mm
150
A
9
6 8
1-25