Immergas VICTRIX 24 TT 1E Instruction And Warning Book page 33

Hide thumbs Also See for VICTRIX 24 TT 1E:
Table of Contents

Advertisement

Id
Parameter
Parameter
Central heating
set point min-
t0
Defines the minimum flow temperature.
imum temper-
ature
Central heating
set point max-
t1
Defines the maximum flow temperature.
imum temper-
ature
Establishes the switch-off method in DHW mode.
1 and 3
t2
DHW thermostat
0 and 2
The boiler is set to switch-on immediately after a request. for DHW In the case of
coupling with a solar storage tank positioned upstream from the boiler, it is possible to
Solar delay
t3
compensate the distance between the storage tank and the boiler in order to allow the
timing
water to reach the boiler. Set the time necessary to verify that the water is hot enough
(see par. Solar panels coupling)
In winter mode the boiler, at the end of a domestic hot water request, is ready to switch
Domestic hot
to central heating mode if there is an active request. Timing sets a time period in which
t4
water priority
the boiler waits before changing the operating mode, in order to quickly and comfortably
timing
satisfy an additional request for domestic hot water.
Central heating
The boiler has electronic timing, which prevents the burner from igniting too often in
t5
ignitions timer
central heating mode
Central heating
In the heating stage, the boiler performs an ignition ramp in order to reach the maxi-
t6
ramp timer
mum output set
CH ignition de-
The boiler is set to switch-on immediately after a request. In the event of particular
t7
lay from TA and
systems (e.g. area systems with motorised thermostatic valves etc.) it may be necessary
CR request
to delay ignition
Establishes the display lighting mode.
0 Automatic: the display lights up during use and dims after 15 seconds of inactivity. In
t8
Display lighting
1 Low: the display is always lit with low intensity
2 High: the display is always lit with high intensity.
Establishes what the indicator displays 14 (Fig. 2-1).
"Summer" mode:
0:
1:
t9
Display
"Winter" mode:
0:
1:
Id
Parameter
Parameter
A0
Hydraulic model Defines the type of hydraulics in the boiler
A1
-
Not used on this boiler model
Model
A2
Defines the type of circulator in the boiler
Pump
A3
-
Not used on this boiler model
A4
-
Not used on this boiler model
A5
-
Not used on this boiler model
Id
Parameter
Parameter
Equivalent length
F0
Defines the length of the flue (see par. 3.10)
flue
F1
-
Not used on this boiler model
In the event of an alteration, anomaly "E72" appears and fast calibration is required.
Correlated: the boiler switches off according to the temperature set.
Fixed: the switch-off temperature is fixed at the maximum value regardless
of the value set on the control panel.
the event of an anomaly the display flashes.
the indicator is always off
circulator active, it displays the flow temperature
pump off the indicator is off
it always displays the value set on the central heating selector
circulator active, it displays the flow temperature
pump off always displays the value set on the CH selector
Description
Description
Description
33
Range
Default
20 ÷ 50 °C
25
(t0+5) ÷ 85
85
°C
0 - 3
0
0 - 30 seconds
0
0 - 100 sec-
onds
2
(step 10 sec)
0 - 600 sec-
onds
18
(step 10 sec)
0 - 840
seconds
18
(step 10 sec)
0 - 600 sec-
onds
0
(step 10 sec)
0 - 2
0
0 - 1
1
Range
Default
Set
0
0
-
-
Set
0
0
-
-
-
-
-
-
Range
Default
0 - 2
0
-
-