MACHINE PROGRAMMING CONT'D
Set Temperature
170 to 205 degrees Fahrenheit with the default at 200 degrees F. Pressing button D (see Fig 1)
will toggle the display so the user may view the real tank temperature. The real temperature
display has all three decimal points illuminated. Pressing button D (see Fig 1) again will switch
the display back to show the current set point. As with most of the entries, button A and button
B (see Fig 1) will change the set point, incrementing or decrementing by one. Pressing the Hot
Water key (G)(see Fig 1) will exit.
Set Energy Save Mode
Use button A and button B (see Fig 1) to change the entry then press the Hot Water (G) key to
exit.
Off Mode (default) –No Energy Save
Energy Save– Partial Power Save Mode. After the user selectable time out the tank
temperature set point is set to 180 until a key is pressed. When this mode is selected the
right most decimal point in the display is on.
Full Energy Save – Full Power Save Mode. After the user selectable time out the tank heater
is disabled until a key is pressed. When this mode is selected the left most decimal point in
the display is on.
Set Energy Save Time
has been turned off. This entry sets the time the machine will operate normally until the power
save function is activated. The user can choose 1 through 4 hours in 1-hour increments with the
default set to 4 hours. As with most of the entries, button A and button B (see Fig 1) will change
the time, incrementing or decrementing by one. Pressing the Hot Water key (G) (see Fig 1) will
exit.
Set Buzzer Volume
Set Air Pump Speed
of 5 to 10 strength with the default at 9. As with most of the entries button A and button B (see
Fig 1) will change the Air Pump Strength, incrementing or decrementing by one. Pressing the
Hot Water key (G)( (see Fig 1) key will exit.
Set Air Pump Time
10 seconds with the default at 5. As with most of the entries button A and button B (see Fig 1)
will change the Air Pump Time, incrementing or decrementing by one. Pressing the Hot Water
key (G) (see Fig 1) key will exit.
Set Pod Count
before signaling that the bin is full. The range is 10 to 100 pods, with the default at 40. Setting
the pod count under 10 turns off the count so the bin full alarm will never go off. As with most of
the entries button A and button B (see Fig 1) will change the Pod Count threshold, incrementing
or decrementing by one. Pressing the Hot Water key (G) (see Fig 1) will exit.
: In this entry the user may set the tank temperature in the range of
: This entry allows the user to select the Power Save mode.
: This entry will not be displayed if the Power Save function
: The range is from 1 to 24. The default is 13.
: In this entry the user may set the air pump strength in the range
: In this entry the user may set the air pump time in the range of 2 to
: In this entry the user may set the number of pods the brewer will hold
9