MACHINE PROGRAMMING CONT'D
Flowmeter Adjustment
of liquid for one tick of the flow meter count. Each tick adjusts the value approximately 2/10
an ounce. While in this entry, pressing the A key will decrement and the B key will increment
this value. This can be used to fine-tune the amount of liquid that is dispensed. The default
value is 0.
Recipe Settings
unique to each key. When this entry is accessed the display will change to SELECT BUTTON
indicating that the user should press the brew key (button B, C or D, E or F (see Fig 1)) to be
programmed. When a brew key is selected the display will show the first entry in the Button Set
up sub menu, PRE-INFUSION. While SELECT BUTTON is displayed the user may exit back to the
Main menu by Pressing the Hot Water key (G) (see Fig 1).
With these four entries in the BUTTON SET UP sub menu:
SET PRE-INFUSION TIME
tenths of a second. Range is 1 to 30, the default is 15 tenths of a seconds.
SET BREW VOLUME
dispense. The Range is from 20 to 160 tenths of an ounce with the default set to 70 tenths of
an ounce
SET BREW TIME
on/off pulses. The range is from ~30 to 99 seconds with the default being 35 seconds.
EXIT
: Exit to Main Programming Menu.
Select Water Filter
on the inlet for the water. Choices include OFF, 500 GAL UP TO 3000 GAL. These set the counter
for the filter warning. Whenever water is dispensed the counter is incremented to account for
the water dispensed. When the counter is above 90% of the capacity of the chosen filter a
warning message, "CHECK FILTRATION ", is displayed in place of the "READY" message. To
reset the counter the user must enter the programming menu and enter the RESET FILTER entry
described below. The following entries only show when a filter is selected. If the filter selection
is OFF then following entries are not available. Pressing the Hot Water key (G) (see Fig 1) to
leave the entry and return to the Main Programming menu.
GAL. REMAINING
replaced. Pressing the Hot Water key (G) (see Fig 1) to leave the entry and return to the Main
Programming menu.
: When in this entry the message "PRESS OPEN TO RESET FILTER'. Press the
RESET FILTER
Open Door key will reset the Filter Use counter to the value chosen in the SELECT WATER
FILTER entry above. Pressing the Hot Water key (G) (see Fig 1) to leave the entry and return to
the Main Programming menu.
EXIT MENU:
:
This entry displays the value used to represent the amount
: This entry takes the user into a sub menu to program the parameters
: This entry sets the time of the pre-infusion pulse of water in
: This entry sets the volume in tenths of an ounce for this key to
: This entry sets the brew time in seconds for a 7-ounce cup of coffee with
: This entry allows the user to select the filter size for the filter used
: This entry scrolls the number of Gallons left before the filter should be
– Exit to Ready to Brew Mode and save parameters.