10.8
Gamma correction
The gamma correction is changeable.
GenICam Parameters
Gamma
10.9
ROI (Region of Interest)
The specified region of image can be output from camera with ROI function.
GenICam Paramters
Width
Height
OffsetX
OffsetY
The ROI region settings are below:
STC-MBS202POE / STC-MCS202POE
Product Specifications and User's Guide
IFloat Type
Gamma correction
Range: 0 to 4.0
Default: 1.0
IInteger Type
Width (horizontal size) of output image (in pixel)
Range: 8 to 1,624
Default: 1,624
Adjustable steps: 8
("Width" + "Offset X") should not exceeded maximum width.
IInteger Type
Height (vertical size) of output image (in line)
Range: 8 to 1,240
Default: 1,240
Adjustable steps: 8
("Height" + "Offset Y") should not exceeded maximum height.
IInteger Type
Horizontal offset for output image (in pixel)
Range: 0 to 1,616
Default: 0
Adjustable steps: 8
IInteger Type
Vertical offset for output image (in line)
Range: 0 to 1,232
Default: 0
Adjustable steps: 8
ROI region
OffsetX
Width
OffsetY
Height
No.18S110-02
47/71