2.6 TROUBLESHOOTING.

The Hercules Condensing ErP boiler signals
any anomalies by the flashing symbol (5) along
with the "ERRxx" indication on the indicator
(6) where "xx" corresponds to the error code
described in the following table. On the remote
control, the error code will be displayed by means
of the same numeric code represented according
to the following example (e.g. CAR
V2
CAR = ERR>xx).
Error
Anomaly signalled
Code
01
No ignition block
Safety thermostat
block (overheat-
02
ing), flame control
or fumes thermo-
fuse anomaly
Flue safety thermo-
03
stat block
Contacts resistance
04
block
Flow probe
05
anomaly
Maximum N° of
08
reset
Insufficient system
10
pressure
Storage tank probe
12
anomaly
Configuration error
15
16
Fan anomaly
Parasite flame
20
block
General alarm
22
Return probe
23
anomaly
Push button control
24
panel anomaly
Block due to flue
gas temperature
25
gradient interven-
tion
Insufficient circula-
27
tion
(1) If the shutdown or fault persists, contact an authorised firm (e.g. Authorised Technical After-Sales Service).
= Exx, Super
Cause
In the event of request of room central heating or domestic hot water
production, the boiler does not switch on within the preset time. Upon
appliance commissioning or after extended downtime, it may be neces-
sary to eliminate the block.
During normal operation, if a fault causes excessive overheating internally,
the boiler goes into overheating block.
During normal operation, if a fault causes excessive flue gas overheating,
the boiler blocks
Safety thermostat fault (overheating) or flame control anomaly.
The board detects an anomaly on the flow NTC probe.
Number of allowed resets that have already performed.
Water pressure inside the central heating circuit that is sufficient to guar-
antee the correct operation of the boiler is not detected.
The board detects an anomaly on the storage tank probe.
If the board detects an anomaly or incongruity on the electric wiring, the
boiler will not start.
This occurs if the fan has a mechanical or electrical fault.
This occurs in the event of a leak on the detection circuit or anomaly in
the flame control unit.
This type of error is displayed on the CAR
in the event of faults or anomalies of the circuit boards or components not
directly connected to boiler management: anomaly on the zones control
unit, substation or solar circuit.
The board detects an anomaly on the return NTC probe
The board detects an anomaly on the pushbutton panel
If the board detects a rapid increase in flue gas temperature probably due
to a blocked circulating pump or lack of water in the heat exchanger, the
boiler shuts down due to the flue gas temperature gradient trip.
This occurs if there is overheating in the boiler due to insufficient water
circulating in the primary circuit; the causes can be:
- low system circulation; check that no shut-off devices are closed on the
heating circuit and that the system is free of air (deaerated);
- pump blocked; free the pump.
or Super CAR remote control
V2
24
Boiler status / Solution
Press the Reset button (1)
Press the Reset button (1)
Press the Reset button (1)
Press the Reset button (1)
The boiler does not start (1)
Attention: the anomaly can be reset 5 times
consecutively, after which the function in
inhibited for at least one hour. One attempt
is gained every hour for a maximum of 5
attempts. By switching the appliance on and
off the 5 attempts are re-acquired.
Check on the boiler pressure gauge (1) that
the system pressure is between 1÷1.2 bar
and restore the correct pressure if necessary.
The boiler cannot produce domestic hot
water, domestic water heating is carried
out by the solar system and Pdc (1).
If normal conditions are restored the boiler
restarts without having to be reset (1)
Press the Reset button (1)
Press the Reset button (1)
(1)
The boiler does not start (1)
If normal conditions are restored the
boiler restarts without having to be reset
(1)
Press the Reset button (1)
Press the Reset button (1).