1.Important Safety Information installation procedures and receiving approval from the electric utility company. Please be kindly noted that the Envertech microinverter itself is a heat sink. Under normal 1.1 Read it First operating conditions, its temperature is 20°C above ambient, but under extreme conditions This manual contains important instructions for installation and maintenance of the the microinverter can reach a temperature of 80°C.
PV system. Envertech Microinverters are designed to operate at full power at ambient temperatures as EVT560 can be adapted to almost all 60-cell or 72-cell modules. Before installation, please high as +65℃(150℉). The microinverter casing is designed for outdoor installation and check the parameters of the microinverters and modules to ensure that they are complies with the IP67 protection level.
4.1 Accessories This device SHALL NOT be disposed of in residential wastePlease go to After you receive the Envertech microinverter, please check if there is any damage on the Chapter 9 “Recycling and Disposal” for proper treatments. carton, and then check the inside completeness for any visible external damage on the microinverter and accessories.
AC extension cable Installing Envertech microinverter system involves several key steps. Each step listed here (AWG12 or above) is elaborated on the following pages. Step 1: Mount microinverters onto the rack...
Page 7
Step 4: Fasten AC cables Step 1:Mount microinverters onto the rack Fasten AC cables and grounding cables to the rack with cable ties. Mark out the estimated center of each PV module on the rack to facilitate locating microinverters.. Mount all microinvertes under modules to avoid rain and sun, with the trademark facing downward.
Page 8
Step 8: Prepare AC extension cable. It is suggested to use extension cable of AWG12 above (same or higher than Envertech AC cable standard). 1. Remove the skin of the two ends of the extension cable by y=40mm and remove the skin of internal wires by x=14mm.
Envertech microinverters begin to communicate through the power lines to EnverBridge. The entire system will be detected within 10 minutes. 4. The voltage and frequency of EVT560 can be adjusted on the site. If adjustments are required by your local utility company, installers can use EnverBridge to manage grid parameters after all microinverters have been detected.
To troubleshoot an inoperable microinverter, follow the steps in the order shown below. If your problems are still unsolved with the steps above, please contact Envertech tech WARNING: Be aware that only qualified personnel should troubleshoot the PV array or the support through www.envertec.com.
261 mm length 1839 mm length 1839 mm length 2100 mm Microinverter(n=10) Zhejiang Envertech Corporation Ltd. Tel: +86 579 8926 6326 Web: www.envertec.com Email:info@envertec.com Add:24th Floor, Jintong Mansion, Center of Headquarters, Yongkang City, length 1839 mm length 261 mm...
Need help?
Do you have a question about the EVT560 and is the answer not in the manual?