EnverPortal: http://www.envertecportal.com 1.2 Safety Instructions Do not use Envertech equipment in a manner not speci ed by the manufacturer. Doing so may cause death or injury to persons, or damage to equipment. Be aware that only quali ed personnel should install or replace the Envertech microinverters and the Cable and accessories.
EVT360 can be adapted to almost all 60-cell or 72-cell modules. Before installation, in the PV system. Envertech Microinverters are designed to operate at full power at please check the parameters of the microinverters and modules to ensure that they ambient temperatures as high as +65℃(150℉).
4.1 Accessories No unauthorized perforations or modi cations After you receive the Envertech microinverter, please check if there is any damage on the carton, Any unauthorized perforations or modi cations are strictly forbidden. If any and then check the inside completeness for any visible external damage on the microinverter and defect or damage (device/person) is occurred, Envertech shall not take any accessories.
AC cable. Cable Model Selection Please make sure that there are less than 8 units of EVT360 in each branch (12AWG). To install the AC Bus Cable, you just simply unroll the cable to the needed length to make the cut.
Page 7
4. Fasten AC cables Wi-Fi configuration setting Fasten AC cables and grounding cables to the rack with cable ties. b) Open EnverView and click Wi-Fi a) Connect network whose name is as Setting. same as your monitor’s SN in your cellphone.
Page 8
Step 9: Connect PV modules to microinvert- Mount the PV modules on top of microin- verters; Connect each PV module with the DC input cables of the microinverter. Step 10: Switch on the PV system Ensure all connection is completed and then turn on the air switch. Step 3: Click “Confirm”...
Bridge. The entire system will be detected within 10 minutes. Settings—Management”. 4. The voltage and frequency of EVT360 can be adjusted on the site. If adjustments are required by your local utility company, installers can use EnverBridge to manage grid parameters after all microinverters have been detected.
Best Practice: Please do not disconnect DC connection while the system is working. Ensure If your problems are still unsolved with the steps above, please contact Envertech tech that no current is flowing in the DC wires prior to disconnecting. If necessary, use an opaqueto support through www.envertec.com.
746 mm length 1050 mm length 1050 mm length 304 mm Mic roinverter(n=17) Zhejiang Envertech Corporation Ltd. Tel: +86 579 8926 6326 Web: www.envertec.com Email:info@envertec.com Add:24th Floor, Jintong Mansion, Center of Headquarters, Yongkang City, length 746 mm length 1050 mm...