5 Configuration
#
Code
[5.2]
[6-0A]
Comfort setpoint
▪ 30°C~[6‑0E]°C
Eco setpoint
The storage economic temperature denotes the lower desired
tank temperature. It is the desired temperature when a storage
economic action is scheduled (preferably during day).
#
Code
[5.3]
[6-0B]
Eco setpoint
▪ 30°C~min(50,[6‑0E])°C
Reheat setpoint
Desired reheat tank temperature, used:
▪ in Schedule + reheat mode, during reheat mode: the guaranteed
minimum tank temperature is set by the Reheat setpoint minus the
reheat hysteresis. If the tank temperature drops below this value,
the tank is heated up.
▪ during storage comfort, to prioritize the domestic hot water
preparation. When the tank temperature rises above this value,
domestic hot water preparation and space heating/cooling are
executed sequentially.
#
Code
[5.4]
[6-0C]
Reheat setpoint
▪ 30°C~min(50,[6‑0E])°C
5.3

Settings menu

You can set additional settings using the main menu screen and its
submenus. The most important settings are presented here.
5.3.1

Main zone

Thermostat type
Only applicable in external room thermostat control.
NOTICE
If an external room thermostat is used, the external room
thermostat will control the room frost protection. However,
the room frost protection is only possible if the leaving
water temperature control on the unit's user interface is
turned ON.
#
Code
[2.A]
[C–05]
External room thermostat type for the
main zone:
▪ 1: 1 contact: The used external room
thermostat can only send a thermo
ON/OFF
separation between heating or cooling
demand.
▪ 2: 2 contacts: The used external room
thermostat
heating/cooling
condition.
5.3.2

Additional zone

Thermostat type
Only applicable in external room thermostat control. For more info
about the functionality, see
"5.3.1 Main zone" on
Installation manual
18
Description
Description
Description
Description
condition.
There
is
no
can
send
a
separate
thermo
ON/OFF
page 18.
#
Code
[3.A]
[C–06]
External room thermostat type for the
additional zone:
▪ 1: 1 contact
▪ 2: 2 contacts
5.3.3

Information

Dealer information
The installer can fill in his contact number here.
#
Code
[8.3]
N/A
Number that users can call in case of
problems.